跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

物理学 > 医学物理

arXiv:1609.08208 (physics)
[提交于 2016年9月26日]

标题:Detecting Aortic Valve Opening and Closing from Distal Body Vibrations

作者:Andrew D. Wiens, Ann Johnson, Omer T. Inan
查看论文《Detecting Aortic Valve Opening and Closing from Distal Body Vibrations》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Objective: Proximal and whole-body vibrations are well studied in seismocardiography and ballistocardiography, yet distal vibrations are still poorly understood. In this paper we develop two methods to measure aortic valve opening (AVO) and closing (AVC) from distal vibrations. Methods: AVO and AVC were detected for each heartbeat with accelerometers on the upper arm (A), wrist (W), and knee (K) of 22 consenting adults following isometric exercise. Exercise-induced changes were recorded with impedance cardiography, and nine-beat ensemble averaging was applied. Our first method, FilterBCG, detects peaks in distal vibrations after filtering with individually-tuned bandpass filters while RidgeBCG uses ridge regression to estimate AVO and AVC without peaks. Pseudocode is provided. Results: In agreement with recent studies, we did not find peaks at AVO and AVC in distal vibrations, and the conventional R-J interval method from the literature also correlated poorly with AVO (r2 = 0.22 A, 0.14 W, 0.12 K). Interestingly, distal vibrations filtered with FilterBCG resembled seismocardiogram signals and yielded reliable peaks at AVO (r2 = 0.95 A, 0.94 W, 0.77 K) and AVC (r2 = 0.92 A, 0.89 W, 0.68 K). Conclusion: FilterBCG measures AVO and AVC accurately from arm, wrist, and knee vibrations, and it outperforms R-J intervals and RidgeBCG. Significance: To our knowledge, this study is the first to measure AVC accurately from distal vibrations. Finally, AVO timing is needed to assess cardiovascular disease risk with pulse wave velocity (PWV) and for cuff-less diastolic blood pressure measurement via aortic pulse-transit time (PTT).
主题: 医学物理 (physics.med-ph)
引用方式: arXiv:1609.08208 [physics.med-ph]
  (或者 arXiv:1609.08208v1 [physics.med-ph] 对于此版本)
  https://doi.org/10.48550/arXiv.1609.08208

提交历史

来自:Andrew Wiens
[v1] 2016年9月26日 星期一 22:10:45 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics.med-ph
< 上一篇   |   下一篇 >
最新 | 近期 | 2016-09
切换浏览方式为:
physics

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站