标题:Improved liver T1rho measurement precision with a breathhold black blood single shot fast spin echo acquisition: a validation study in healthy volunteers

作者:Yi-Xiang Wang, Min Deng, GladsG Lo, Queenie Chan, Jing Yuan, Weitian Chen
查看论文《Improved liver T1rho measurement precision with a breathhold black blood single shot fast spin echo acquisition: a validation study in healthy volunteers》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Purpose: To explore the usability and normal T1rho value of liver parenchyma with a novel single breathhold black blood single shot fast spin echo acquisition based liver imaging sequence. Materials and Methods: In total 19 health subjects (10 males, 9 females; mean age: 37.4 yrs; range: 23-54 yrs) participated in the study. 11 subjects had liver scanned twice in the same session to access scan-rescan repeatability. 12 subjects had liver scanned twice in two sessions with 7-10 days' interval to access scan-rescan reproducibility. MR was performed with a 3.0 T scanner with dual transmitter. The MR sequence allows simultaneous acquisition of 4 spin lock times (TSLs: 0ms, 10 ms, 30 ms, 50ms) in 10 second. Inherent black blood effect of fast spin echo and double inversion recovery were utilized to achieve blood signal suppression. Results: The technique demonstrated good image quality and minimal artifacts. For liver parenchyma, Bland-Altman plot showed the scan-rescan repeatability mean difference was 0.025 ms (95% limits of agreement: -1.163 to 1.213 ms), and intraclass correlation coefficient (ICC) was 0.977. The scan-rescan reproducibility mean difference was -0.075 ms (95% limits of agreement: -3.280 to 3.310 ms), and ICC was 0.820 which is better than the ICC of 0.764 of a previous bright blood multi-breath hold gradient echo acquisition technique. The liver T1rho value was 39.9 +/- 2.4 ms (range: 36.1 - 44.2 ms), which is lower than the value of 42.8=/-2.1 ms acquired with the previous bright blood technique. Conclusion: This study validated the application of a single breathhold black blood single shot fast spin echo acquisition based for human liver T1rho imaging. The lower liver parenchyma T1rho value and higher scan rescan reproducibility may improve of the sensitivity of this technique.
评论: Total 30 pages, 4 figures, 1 table
主题: 组织与器官 (q-bio.TO); 医学物理 (physics.med-ph)
引用方式: arXiv:1610.07767 [q-bio.TO]
  (或者 arXiv:1610.07767v1 [q-bio.TO] 对于此版本)
  https://doi.org/10.48550/arXiv.1610.07767

提交历史

来自:Yi-Xiang Wang
[v1] 2016年10月25日 星期二 07:46:45 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

q-bio.TO
< 上一篇   |   下一篇 >
最新 | 近期 | 2016-10
切换浏览方式为:
q-bio
physics.med-ph

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站