arXiv:1611.02299 (physics)
[提交于 2017年12月21日]

标题:Measuring the Magnetic Flux Density with Flux Loops and Hall Probes in the CMS Magnet Flux Return Yoke

作者:B. Curé, N. Amapane, A. Ball, A. Gaddi, H. Gerwig, A. Hervé, V. I. Klyukhin, R. Loveless, M. Mulders
查看论文《Measuring the Magnetic Flux Density with Flux Loops and Hall Probes in the CMS Magnet Flux Return Yoke》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:The Compact Muon Solenoid (CMS) is a general purpose detector, designed to run at the highest luminosity at the CERN Large Hadron Collider (LHC). Its distinctive features include a 4 T superconducting solenoid with 6-m-diameter by 12.5-m-length free bore, enclosed inside a 10,000-ton return yoke made of construction steel. The flux return yoke consists of five dodecagonal three-layered barrel wheels and four end-cap disks at each end comprised of steel blocks up to 620 mm thick, which serve as the absorber plates of the muon detection system. To measure the field in and around the steel, a system of 22 flux loops and 82 3-D Hall sensors is installed on the return yoke blocks. A TOSCA 3-D model of the CMS magnet is developed to describe the magnetic field everywhere outside the tracking volume that was measured with the field-mapping machine. The voltages induced in the flux loops by the magnetic flux changing during the CMS magnet standard ramps down are measured with six 16-bit DAQ modules. The off-line integration of the induced voltages reconstructs the magnetic flux density in the yoke steel blocks at the operational magnet current of 18.164 kA. The results of the flux loop measurements during three magnet ramps down are presented and discussed.
评论: 3 pages, 6 figures, presented at the IEEE Nuclear Science Symposium 2016 (NSS) in Strasbourg, France on November 3, 2016. arXiv admin note: text overlap with arXiv:1605.08778
主题: 仪器与探测器 (physics.ins-det)
引用方式: arXiv:1611.02299 [physics.ins-det]
  (或者 arXiv:1611.02299v1 [physics.ins-det] 对于此版本)
  https://doi.org/10.48550/arXiv.1611.02299
期刊参考: Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop (NSS/MIC/RTSD), 2016
相关 DOI: https://doi.org/10.1109/NSSMIC.2016.8069888

提交历史

来自:Vyacheslav Klyukhin
[v1] 2017年12月21日 星期四 00:00:00 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics.ins-det
< 上一篇   |   下一篇 >
最新 | 近期 | 2017-12
切换浏览方式为:
physics

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站