标题:Sleep Apnea Detection Based on Thoracic and Abdominal Movement Signals of Wearable Piezo-Electric Bands

作者:Yin-Yan Lin, Hau-tieng Wu, Chi-An Hsu, Po-Chiun Huang, Yuan-Hao Huang, Yu-Lun Lo
查看论文《Sleep Apnea Detection Based on Thoracic and Abdominal Movement Signals of Wearable Piezo-Electric Bands》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Physiologically, the thoracic (THO) and abdominal (ABD) movement signals, captured using wearable piezo-electric bands, provide information about various types of apnea, including central sleep apnea (CSA) and obstructive sleep apnea (OSA). However, the use of piezo-electric wearables in detecting sleep apnea events has been seldom explored in the literature. This study explored the possibility of identifying sleep apnea events, including OSA and CSA, by solely analyzing {one or both the THO and ABD signals. An adaptive non-harmonic model was introduced to model the THO and ABD signals, which allows us to design features for sleep apnea events. To confirm the suitability of the extracted features, a support vector machine was applied to classify three categories -- normal and hypopnea, OSA, and CSA. According to a database of} 34 subjects, the overall classification accuracies were on average $75.9\%\pm 11.7\%$ and $73.8\%\pm 4.4\%$, respectively, based on the cross validation. When the features determined from the THO and ABD signals were combined, the overall classification accuracy became $81.8\%\pm 9.4\%$. These features were applied for designing a state machine for online apnea event detection. Two event-by-event accuracy indices, S and I, were proposed for evaluating the performance {of the state machine. For the same database, the} S index was $84.01\%\pm 9.06\%$, and the I index was $77.21\%\pm 19.01\%$. The results indicate the considerable potential of applying the proposed algorithm to clinical examinations for both screening and homecare purposes.
主题: 医学物理 (physics.med-ph); 数据分析、统计与概率 (physics.data-an); 应用 (stat.AP)
引用方式: arXiv:1612.04185 [physics.med-ph]
  (或者 arXiv:1612.04185v1 [physics.med-ph] 对于此版本)
  https://doi.org/10.48550/arXiv.1612.04185

提交历史

来自:Hau-tieng Wu
[v1] 2016年11月22日 星期二 02:09:25 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics.med-ph
< 上一篇   |   下一篇 >
最新 | 近期 | 2016-11
切换浏览方式为:
physics
physics.data-an
stat.AP

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站