标题:Modulation calorimetry in diamond anvil cells II: Joule-heating design and prototypes

作者:Zachary M. Geballe, Viktor V. Struzhkin, Andrew Townley, Raymond Jeanloz
查看论文《Modulation calorimetry in diamond anvil cells II: Joule-heating design and prototypes》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Part I shows that quantitative measurements of heat capacity are theoretically possible inside diamond anvil cells via high-frequency Joule heating (100 kHz to 10 MHz), opening up the possibility of new methods to detect and characterize transformations at high-pressure such as the glass transitions, melting, magnetic orderings, or the onset of superconductivity. Here we test the possibility outlined in Part I, using prototypes and detailed numerical models. First, a coupled electrical-thermal numerical model shows that specific heat of metals inside diamond cells can be measured directly using $\sim 1$ MHz frequency, with $< 10%$ accuracy. Second, we test physical models of high-pressure experiments, i.e. diamond-cell mock-ups. Metal foils of 2 to 6 $\mu$m-thickness are clamped between glass insulation inside diamond anvil cells. Fitting data from 10 Hz to $\sim 30$ kHz, we infer the specific heat capacities of Fe, Pt and Ni with $\pm 20$ to $30%$ accuracy. The electrical test equipment generates -80 dBc spurious harmonics which overwhelm the thermally-induced harmonics at higher frequencies, disallowing the high precision expected from numerical models. An alternative Joule-heating calorimetry experiment, on the other hand, does allow absolute measurements with $< 10%$ accuracy, despite the -80 dBc spurious harmonics: the measurement of thermal effusivity, $\sqrt{\rho c k}$ ($\rho$, $c$ and $k$ being density, specific heat and thermal conductivity), of the insulation surrounding a thin-film heater. Using a $\sim 50$ nm-thick Pt heater surrounded by glass and 10 Hz to 300 kHz frequency, we measure thermal effusivity with $\pm 6%$ accuracy inside the sample chamber of a diamond anvil cell.
主题: 材料科学 (cond-mat.mtrl-sci)
引用方式: arXiv:1701.01873 [cond-mat.mtrl-sci]
  (或者 arXiv:1701.01873v1 [cond-mat.mtrl-sci] 对于此版本)
  https://doi.org/10.48550/arXiv.1701.01873
相关 DOI: https://doi.org/10.1063/1.4979850

提交历史

来自:Zachary Geballe
[v1] 2017年4月26日 星期三 00:00:00 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

cond-mat.mtrl-sci
< 上一篇   |   下一篇 >
最新 | 近期 | 2017-04
切换浏览方式为:
cond-mat

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站