标题:The use of distributed thermal storage in district heating grids for demand side management

作者:Dirk Vanhoudt, Bert Claessens, Robbe Salenbien, Johan Desmedt
查看论文《The use of distributed thermal storage in district heating grids for demand side management》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:The work presented in this paper relates to a small scale district heating network heated by a gas fired CHP. In most common situations, such a CHP is heat driven operated, meaning that the CHP will switch on whenever heat is needed, while not taking into account the demand of electricity at that time. In this paper however, an active control strategy is developed, aiming to maximize the profit of the CHP, selling its electricity to the spot market. The CHP will therefore switch on at moments of high electricity prices. Nevertheless, since there never is a perfect match between the demand of heat and the demand of electricity, a thermal energy storage is included in the network to overcome the difference between supply and demand of heat in the network. In this study, three different storage concepts are compared: (1) a central buffer tank next to the CHP; (2) small storage vessels distributed over the different connected buildings; and (3) the use of the thermal mass if the buildings as storage capacity. Besides the development of the control algorithms based on model predictive control, a simulation model of the network is described to evaluate the performance of the different storage concept during a representative winter week. The results show that the presented control algorithm can significantly influence the heat demand profile of the connected buildings. As a results, active control of the CHP can drastically increase the profit of the CHP. The concept with the distributed buffers gives the best results, however the profit for the thermal mass concept is only marginally smaller. Since in this latter case no significant investment costs are needed, the conclusion for this case study is that the use of thermal mass of buildings for demand side management in district heating systems is very promising.
主题: 系统与控制 (eess.SY); 系统与控制 (cs.SY)
引用方式: arXiv:1702.06005 [eess.SY]
  (或者 arXiv:1702.06005v1 [eess.SY] 对于此版本)
  https://doi.org/10.48550/arXiv.1702.06005

提交历史

来自:Dirk Vanhoudt
[v1] 2017年2月6日 星期一 10:55:24 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

eess.SY
< 上一篇   |   下一篇 >
最新 | 近期 | 2017-02
切换浏览方式为:
eess
cs.SY

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站