标题:Reconstruction by Calibration over Tensors for Multi-Coil Multi-Acquisition Balanced SSFP Imaging

作者:Erdem Biyik, Efe Ilicak, Tolga Çukur
查看论文《Reconstruction by Calibration over Tensors for Multi-Coil Multi-Acquisition Balanced SSFP Imaging》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Purpose: To develop a rapid imaging framework for balanced steady-state free precession (bSSFP) that jointly reconstructs undersampled data (by a factor of R) across multiple coils (D) and multiple acquisitions (N). To devise a multi-acquisition coil compression technique for improved computational efficiency. Methods: The bSSFP image for a given coil and acquisition is modeled to be modulated by a coil sensitivity and a bSSFP profile. The proposed reconstruction by calibration over tensors (ReCat) recovers missing data by tensor interpolation over the coil and acquisition dimensions. Coil compression is achieved using a new method based on multilinear singular value decomposition (MLCC). ReCat is compared with iterative self-consistent parallel imaging (SPIRiT) and profile encoding (PE-SSFP) reconstructions. Results: Compared to parallel imaging or profile-encoding methods, ReCat attains sensitive depiction of high-spatial-frequency information even at higher R. In the brain, ReCat improves peak SNR (PSNR) by 1.1$\pm$1.0 dB over SPIRiT and by 0.9$\pm$0.3 dB over PE-SSFP (mean$\pm$std across subjects; average for N=2-8, R=8-16). Furthermore, reconstructions based on MLCC achieve 0.8$\pm$0.6 dB higher PSNR compared to those based on geometric coil compression (GCC) (average for N=2-8, R=4-16). Conclusion: ReCat is a promising acceleration framework for banding-artifact-free bSSFP imaging with high image quality; and MLCC offers improved computational efficiency for tensor-based reconstructions.
评论: To be published in Magnetic Resonance in Medicine. http://onlinelibrary.wiley.com/doi/10.1002/mrm.26902/abstract
主题: 医学物理 (physics.med-ph)
引用方式: arXiv:1704.00096 [physics.med-ph]
  (或者 arXiv:1704.00096v1 [physics.med-ph] 对于此版本)
  https://doi.org/10.48550/arXiv.1704.00096
相关 DOI: https://doi.org/10.1002/mrm.26902

提交历史

来自:Erdem Bıyık
[v1] 2017年10月10日 星期二 00:00:00 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics.med-ph
< 上一篇   |   下一篇 >
最新 | 近期 | 2017-10
切换浏览方式为:
physics

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站