物理学 > 原子物理
[提交于 2017年4月6日]
标题:Microwave-clock timescale with instability on order of $10^{-17}$
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读摘要:The fundamental limits of atomic fountains as operational clocks are considered. Four rubidium fountains in operation at the U.S. Naval Observatory for over 5.5 years have demonstrated unprecedented long-term stability for continuously running clocks [1,2]. With only these rubidium fountains, a post-processed timescale can be created that demonstrates superior long-term performance to any individual clock by compensating for occasional frequency steps. By comparing to the world's primary standards we demonstrate instability of this rubidium fountain timescale reaching the mid $10^{-17}$'s and zero drift at the level of $1.3 \times 10^{-19}$/day. We discuss fundamental limits due to common mode behaviour or individual fountain performance that cannot be corrected.
提交历史
来自:Steven Peil[v1] 2017年4月6日 星期四 00:00:00 UTC