标题:Fast dose optimization for rotating shield brachytherapy

作者:Myung Cho, Xiaodong Wu, Hossein Dakhah, Jirong Yi, Ryan T. Flynn, Yusung Kim, Weiyu Xu
查看论文《Fast dose optimization for rotating shield brachytherapy》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Purpose: To provide a fast computational method, based on the proximal graph solver (POGS) - a convex optimization solver using the alternating direction method of multipliers (ADMM), for calculating an optimal treatment plan in rotating shield brachytherapy (RSBT). RSBT treatment planning has more degrees of freedom than conventional high-dose-rate brachytherapy (HDR-BT) due to the addition of emission direction, and this necessitates a fast optimization technique to enable clinical usage. // Methods: The multi-helix RSBT (H-RSBT) delivery technique was considered with five representative cervical cancer patients. Treatment plans were generated for all patients using the POGS method and the previously considered commercial solver IBM CPLEX. The rectum, bladder, sigmoid, high-risk clinical target volume (HR-CTV), and HR-CTV boundary were the structures considered in our optimization problem, called the asymmetric dose-volume optimization with smoothness control. Dose calculation resolution was 1x1x3 mm^3 for all cases. The H-RSBT applicator has 6 helices, with 33.3 mm of translation along the applicator per helical rotation and 1.7 mm spacing between dwell positions, yielding 17.5 degree emission angle spacing per 5 mm along the applicator.// Results: For each patient, HR-CTV D90, HR-CTV D100, rectum D2cc, sigmoid D2cc, and bladder D2cc matched within 1% for CPLEX and POGS. Also, we obtained similar EQD2 figures between CPLEX and POGS. POGS was around 18 times faster than CPLEX. Over all patients, total optimization times were 32.1-65.4 seconds for CPLEX and 2.1-3.9 seconds for POGS. // Conclusions: POGS substantially reduced treatment plan optimization time around 18 times for RSBT with similar HR-CTV D90, OAR D2cc values, and EQD2 figure relative to CPLEX, which is significant progress toward clinical translation of RSBT. POGS is also applicable to conventional HDR-BT.
评论: 9 pages, 3 figures
主题: 医学物理 (physics.med-ph); 优化与控制 (math.OC)
引用方式: arXiv:1704.05610 [physics.med-ph]
  (或者 arXiv:1704.05610v1 [physics.med-ph] 对于此版本)
  https://doi.org/10.48550/arXiv.1704.05610
相关 DOI: https://doi.org/10.1002/mp.12486

提交历史

来自:Myung Cho
[v1] 2017年4月19日 星期三 04:31:39 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics.med-ph
< 上一篇   |   下一篇 >
最新 | 近期 | 2017-04
切换浏览方式为:
physics
math.OC

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站