物理学 > 医学物理

arXiv:1706.08946 (physics)
[提交于 2017年6月27日]

标题:High-Fidelity Modeling of Shift-Variant Focal-Spot Blur for High-Resolution CT

作者:Steven Tilley II, Wojciech Zbijewski, J. Webster Stayman
查看论文《High-Fidelity Modeling of Shift-Variant Focal-Spot Blur for High-Resolution CT》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Dedicated application-specific CT systems are popular solutions to high-resolution clinical needs. Some applications, such as mammography and extremities imaging, require spatial resolution beyond current capabilities. Thorough understanding of system properties may help tailor system design, acquisition protocols, and reconstruction algorithms to improve image quality. Using a high-fidelity measurement model, we analyze the effects of shift-variant focal spot blur due to depth-dependence and anode angulation on image quality throughout the three-dimensional field of view of a simulated extremities scanner. A model of the shift-variant blur associated with this device is then incorporated into a Model-Based Iterative Reconstruction (MBIR) algorithm, which is then compared to FDK and MBIR with simpler blur models at select locations throughout the field of view. We show that shift-variant focal spot blur leads to location-dependent imaging performance. Furthermore, changing the orientation of the X-ray tube alters this spatial dependence. The analysis suggests methods to improve imaging performance based on specific image quality needs. The results also demonstrate that image quality can be improved by combining accurate blur modeling with MBIR. Specifically, across the entire field of view, MBIR with shift-variant blur modeling yielded the best image quality, followed by MBIR with a shift-invariant blur model, MBIR with an identity blur model, and FDK, respectively. These results suggest a number of opportunities for the optimization of imaging system performance in the hardware setup, the imaging protocol, and the reconstruction approach. While the high-fidelity models used here are applied using the specifications of a dedicated extremities imaging system, the methods are general and may be applied to optimize imaging performance in any CT system.
评论: Proceedings of the 14th International Meeting on Fully Three-Dimensional Image Reconstruction in Radiology and Nuclear Medicine, page 752
主题: 医学物理 (physics.med-ph)
引用方式: arXiv:1706.08946 [physics.med-ph]
  (或者 arXiv:1706.08946v1 [physics.med-ph] 对于此版本)
  https://doi.org/10.48550/arXiv.1706.08946

提交历史

来自:Steven Tilley II
[v1] 2017年6月27日 星期二 17:18:36 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics.med-ph
< 上一篇   |   下一篇 >
最新 | 近期 | 2017-06
切换浏览方式为:
physics

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站