标题:A novel TOF-PET MRI detector for diagnosis and follow up of the prostate cancer

作者:F. Garibaldi, S. Beging, R. Canese, G. Carpinelli, N. Clinthorne, S. Colilli, L. Cosentino P. Finocchiaro, F. Giuliani, M. Gricia, M. Lucentini, S. Majewski, E. Monno, P. Musico, F. Santavenere, J. Tödter, H. Wegener, K. Ziemons
查看论文《A novel TOF-PET MRI detector for diagnosis and follow up of the prostate cancer》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Prostate cancer is the most common disease in men and the second leading cause of death from cancer. Generic large imaging instruments used in cancer diagnosis have sensitivity, spatial resolution, and contrast inadequate for the task of imaging details of a small organ such as the prostate. In addition, multimodality imaging can play a significant role merging anatomical and functional details coming from simultaneous PET and MRI. Indeed, multi-parametric PET/MRI was demonstrated to improve diagnosis, but it suffers from too many false positives. In order to address the above limits of the current techniques, we have proposed, built and tested, thanks to the TOPEM project funded by Italian National Institute of Nuclear Phisics a prototype of an endorectal PET-TOF/MRI probe. In the applied magnification PET geometry, performance is dominated by a high-resolution detector placed closer to the source. The expected spatial resolution in the selected geometry is about 1.5 mm FWHM and efficiency a factor of 2 with respect to what obtained with the conventional PET scanner. In our experimental studies, we have obtained timing resolution of ~ 320 ps FWHM and at the same time Depth of Interaction (DOI) resolution of under 1 mm. Tests also showed that mutual adverse PET-MR effects are minimal. In addition, the matching endorectal RF coil was designed, built and tested. In the next planned studies, we expect that benefiting from the further progress in scintillator crystal surface treatment, in SiPM technology and associated electronics would allow us to significantly improve TOF resolution
主题: 医学物理 (physics.med-ph)
引用方式: arXiv:1708.07314 [physics.med-ph]
  (或者 arXiv:1708.07314v1 [physics.med-ph] 对于此版本)
  https://doi.org/10.48550/arXiv.1708.07314

提交历史

来自:Franco Garibaldi Dr
[v1] 2017年8月24日 星期四 08:53:50 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics.med-ph
< 上一篇   |   下一篇 >
最新 | 近期 | 2017-08
切换浏览方式为:
physics

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站