标题:Evaluation of latent variances in Monte Carlo dose calculations with Varian TrueBeam photon phase-spaces used as a particle source

作者:Eyad Alhakeem, Sergei Zavgorodni
查看论文《Evaluation of latent variances in Monte Carlo dose calculations with Varian TrueBeam photon phase-spaces used as a particle source》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Purpose: To evaluate the latent variance (LV) of TrueBeam photon phase-space files (PSF) for open 10x10$cm^2$ and small fields. Methods: BEAMnrc/DOSXYZnrc was used to transport particles from Varian phase-space files (PSFA) through the secondary collimators. Transported particles were scored into another phase-space located under the jaws (PSFB), or transported further through the cone collimators and scored straight below, forming PSFC. PFSB were scored for 6MV-FFF, 6MV, 10MV-FFF, 10MV and 15MV beams with 10x10$cm^2$ field size, and PSFC were scored for 6MV beam under cones of 0.13, 0.25, 0.35, 1.0, 1.2, 1.5 and 4cm diameter. PSFB and PSFC were transported into a water phantom with particle recycling number ranging from 10 to 1000. For 10x10$cm^2$ fields 0.5x0.5x0.5cm^3 voxels were used to score the dose, whereas the dose was scored in 0.1x0.1x0.5cm^3 voxels for beams collimated with small cones. For small 0.25cm diameter cone-collimated 6MV beam, phantom voxel size varied as 0.02x0.02x0.5cm^3, 0.05x0.05x0.5cm^3 and 0.1x0.1x0.5cm^3. Dose variances were scored in all cases and LV evaluated as per Sempau et al. Results: For the 10x10cm^2 fields calculated LVs were greatest at the phantom surface and decreased with depth until reached a plateau at 5cm depth. LVs were 0.54%, 0.96%, 0.35%, 0.69% and 0.57% for the 6MV-FFF, 6MV, 10MV-FFF, 10MV and 15MV energies, respectively at 10cm depth. For the 6 MV phase-space collimated with cones of 0.13, 0.25, 0.35, 1.0cm diameter, the LVs calculated at 1.5cm depth were 75.6%, 25.4%, 17.6% and 8.0% respectively. Calculated LV for the 0.25cm cone-collimated 6MV beam were 61.2%, 40.7%, 22.5% in 0.02x0.02x0.5cm^3, 0.05x0.05x0.5cm^3 and 0.1x0.1x0.5cm^3 voxels respectively. Conclusion: Single PSF can be used to achieve sub-percent latent variance in open 10x10cm^2 field MC simulations, whereas more PSFs would have to be summed for small SRS fields.
评论: 9 pages, 4 figures, 4 tables
主题: 医学物理 (physics.med-ph)
引用方式: arXiv:1708.07538 [physics.med-ph]
  (或者 arXiv:1708.07538v1 [physics.med-ph] 对于此版本)
  https://doi.org/10.48550/arXiv.1708.07538
相关 DOI: https://doi.org/10.1088/1361-6560/aa9f39

提交历史

来自:Eyad Alhakeem
[v1] 2017年8月24日 星期四 19:56:32 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics.med-ph
< 上一篇   |   下一篇 >
最新 | 近期 | 2017-08
切换浏览方式为:
physics

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站