跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

物理学 > 医学物理

arXiv:1708.09526 (physics)
[提交于 2017年8月31日]

标题:Non-invasive acquisition of fetal ECG from the maternal xyphoid process: a feasibility study in pregnant sheep and a call for open data sets

作者:C Shen, MG Frasch, HT Wu, CL Herry, M Cao, A Desrochers, G Fecteau, P Burns
查看论文《Non-invasive acquisition of fetal ECG from the maternal xyphoid process: a feasibility study in pregnant sheep and a call for open data sets》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Objective: The utility of fetal heart rate (FHR) monitoring can only be achieved with an acquisition sampling rate that preserves the underlying physiological information on the millisecond time scale (1000 Hz rather than 4 Hz). For such acquisition, fetal ECG (fECG) is required, rather than the ultrasound to derive FHR. We tested one recently developed algorithm, SAVER, and two widely applied algorithms to extract fECG from a single channel maternal ECG signal recorded over the xyphoid process rather than the routine abdominal signal. Approach: At 126dG, ECG was attached to near-term ewe and fetal shoulders, manubrium and xyphoid processes (n=12). FECG served as the ground-truth to which the fetal ECG signal extracted from the simultaneously-acquired maternal ECG was compared. All fetuses were in good health during surgery (pH 7.29+/-0.03, pO2 33.2+/-8.4, pCO2 56.0+/-7.8, O2Sat 78.3+/-7.6, lactate 2.8+/-0.6, BE -0.3+/-2.4). Main result: In all animals, single lead fECG extraction algorithm could not extract fECG from the maternal ECG signal over the xyphoid process with the F1 less than 50%. Significance: The applied fECG extraction algorithms might be unsuitable for the maternal ECG signal over the xyphoid process, or the latter does not contain strong enough fECG signal, although the lead is near the mother's abdomen. Fetal sheep model is widely used to mimic various fetal conditions, yet ECG recordings in a public data set form are not available to test the predictive ability of fECG and FHR. We are making this data set openly available to other researchers to foster non-invasive fECG acquisition in this animal model.
主题: 医学物理 (physics.med-ph); 数据分析、统计与概率 (physics.data-an); 应用 (stat.AP)
引用方式: arXiv:1708.09526 [physics.med-ph]
  (或者 arXiv:1708.09526v1 [physics.med-ph] 对于此版本)
  https://doi.org/10.48550/arXiv.1708.09526
相关 DOI: https://doi.org/10.1088/1361-6579/aaaaa4

提交历史

来自:Hau-tieng Wu
[v1] 2017年8月31日 星期四 01:34:09 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics.med-ph
< 上一篇   |   下一篇 >
最新 | 近期 | 2017-08
切换浏览方式为:
physics
physics.data-an
stat.AP

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站