摘要:Purpose: Siemens has developed several iterative reconstruction (IR) algorithms on their CT scanners. SAFIRE is available on most of their CT scanners. The latest algorithm, ADMIRE, is available on their newest high-end CT scanners. The aim of our study was to compare the noise reduction properties of the two IR algorithms using objective methods. Methods and Materials: The homogeneous module of the Catphan phantom was scanned on a Siemens AS+ and a Siemens Flash CT scanner using an axial abdomen protocol with fixed tube current at two dose levels. The images were reconstructed with an abdomen filter (B30) using filtered back projection (FBP) and a low, medium, and high level of SAFIRE or ADMIRE. Noise Power Spectrum (NPS) curves were calculated using these images. Then, an anthropomorphic abdomen phantom (Kyoto Kagaku PH-5) was scanned using the same setup and exposure parameters. Fifty axial images at the same slice location were used to calculate inter-image standard deviation maps. Results: At full dose, the median values of the NPS curves were similar for both scanners at all IR levels. At low dose the median values of the NPS curves were generally shifted towards lower spatial frequencies, usually resulting in a more blotchy image texture. This shift was more prominent for ADMIRE compared to SAFIRE for all IR levels. Based on the inter-image standard deviation maps of the anthropomorphic phantom, ADMIRE removed noise near edges more efficiently than SAFIRE. Conclusion: No significant improvement in maintaining noise structure were found for the ADMIRE algorithm. Based on the inter-image standard deviation maps, ADMIRE removed noise near edges more efficiently than SAFIRE.
评论: 10 pages, 5 figures, Submitted to Physica Medica
主题: 医学物理 (physics.med-ph)
引用方式: arXiv:1708.09616 [physics.med-ph]
  (或者 arXiv:1708.09616v1 [physics.med-ph] 对于此版本)
  https://doi.org/10.48550/arXiv.1708.09616

提交历史

来自:Ingvild Dalehaug Ms
[v1] 2017年8月31日 星期四 08:34:13 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics.med-ph
< 上一篇   |   下一篇 >
最新 | 近期 | 2017-08
切换浏览方式为:
physics

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站