跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

天体物理学 > 天体物理仪器与方法

arXiv:1710.03511 (astro-ph)
[提交于 2017年10月10日]

标题:Correcting for the effects of pupil discontinuities with the ACAD method

作者:Johan Mazoyer, Laurent Pueyo, Mamadou N'Diaye, Dimitri Mawet, Rémi Soummer, Colin Norman
查看论文《Correcting for the effects of pupil discontinuities with the ACAD method》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:The current generation of ground-based coronagraphic instruments uses deformable mirrors to correct for phase errors and to improve contrast levels at small angular separations. Improving these techniques, several space and ground based instruments are currently developed using two deformable mirrors to correct for both phase and amplitude errors. However, as wavefront control techniques improve, more complex telescope pupil geometries will soon be a limiting factor for these next generation coronagraphic instru- ments. The technique presented in this proceeding, the Active Correction of Aperture Discontinuities method, is taking advantage of the fact that most future coronagraphic instruments will include two deformable mirrors, and is proposing to find the shapes and actuator movements to correct for the effect introduced by these complex pupil geometries. We here present the results of the parametric analysis realized on the WFIRST pupil for which we obtained high contrast levels with several deformable mirror setups (size, separation between them), coronagraphs (Vortex charge 2, vortex charge 4, APLC) and spectral bandwidths. However, because contrast levels and separation are not the only metrics to maximize the scientific return of an instrument, we also included in this study the influence of these deformable mirror shapes on the throughput of the instrument and sensitivity to pointing jitters. Finally, we present results obtained on another potential space based telescope segmented aperture. The main result of this proceeding is that we now obtain comparable performance than the coronagraphs previously designed for WFIRST. First result from the parametric analysis strongly suggest that the 2 deformable mirror set up (size and distance between them) has a important impact on the performance in contrast and throughput of the final instrument.
评论: Proceedings of the SPIE, Volume 9904, id. 99044T 12 pp. (2016)
主题: 天体物理仪器与方法 (astro-ph.IM)
引用方式: arXiv:1710.03511 [astro-ph.IM]
  (或者 arXiv:1710.03511v1 [astro-ph.IM] 对于此版本)
  https://doi.org/10.48550/arXiv.1710.03511
相关 DOI: https://doi.org/10.1117/12.2232907

提交历史

来自:Johan Mazoyer
[v1] 2017年10月10日 星期二 11:08:50 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

astro-ph.IM
< 上一篇   |   下一篇 >
最新 | 近期 | 2017-10
切换浏览方式为:
astro-ph

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站