标题:A Low-cost Environmental Control System for Precise Radial Velocity Spectrometers

作者:David H. Sliski, Cullen H. Blake, Samuel Halverson
查看论文《A Low-cost Environmental Control System for Precise Radial Velocity Spectrometers》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:We present an Environmental Control System (ECS) designed to achieve milliKelvin (mK) level temperature stability for small-scale astronomical instruments. This ECS is inexpensive and is primarily built from commercially available components. The primary application for our ECS is the high-precision Doppler spectrometer MINERVA-Red, where the thermal variations of the optical components within the instrument represent a major source of systematic error. We demonstrate $\pm 2$ mK temperature stability within a 0.5 m$^{3}$ Thermal Enclosure using resistive heaters in conjunction with a commercially available PID controller and off-the-shelf thermal sensors. The enclosure is maintained above ambient temperature, enabling rapid cooling through heat dissipation into the surrounding environment. We demonstrate peak-to-valley (PV) temperature stability of better than 5 mK within the MINERVA-Red vacuum chamber, which is located inside the Thermal Enclosure, despite large temperature swings in the ambient laboratory environment. During periods of stable laboratory conditions, the PV variations within the vacuum chamber are less than 3 mK. This temperature stability is comparable to the best stability demonstrated for Doppler spectrometers currently achieving 1 m s$^{-1}$ radial velocity precision. We discuss the challenges of using commercially available thermoelectrically cooled CCD cameras in a temperature-stabilized environment, and demonstrate that the effects of variable heat output from the CCD camera body can be mitigated using PID-controlled chilled water systems. The ECS presented here could potentially provide the stable operating environment required for future compact, "astro-photonic" precise radial velocity (PRV) spectrometers to achieve high Doppler measurement precision with a modest budget.
评论: 17 pages, 10 figures, PASP accepted October 2017
主题: 天体物理仪器与方法 (astro-ph.IM)
引用方式: arXiv:1710.04938 [astro-ph.IM]
  (或者 arXiv:1710.04938v1 [astro-ph.IM] 对于此版本)
  https://doi.org/10.48550/arXiv.1710.04938
相关 DOI: https://doi.org/10.1088/1538-3873/aa92c1

提交历史

来自:David Sliski
[v1] 2017年10月13日 星期五 14:24:07 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

astro-ph.IM
< 上一篇   |   下一篇 >
最新 | 近期 | 2017-10
切换浏览方式为:
astro-ph

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站