跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

电气工程与系统科学 > 信号处理

arXiv:1801.03525 (eess)
[提交于 2018年1月10日]

标题:Accelerated Cardiac Diffusion Tensor Imaging Using Joint Low-Rank and Sparsity Constraints

作者:Sen Ma, Christopher T. Nguyen, Anthony G. Christodoulou, Daniel Luthringer, Jon Kobashigawa, Sang-Eun Lee, Hyuk-Jae Chang, Debiao Li
查看论文《Accelerated Cardiac Diffusion Tensor Imaging Using Joint Low-Rank and Sparsity Constraints》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Objective: The purpose of this manuscript is to accelerate cardiac diffusion tensor imaging (CDTI) by integrating low-rankness and compressed sensing. Methods: Diffusion-weighted images exhibit both transform sparsity and low-rankness. These properties can jointly be exploited to accelerate CDTI, especially when a phase map is applied to correct for the phase inconsistency across diffusion directions, thereby enhancing low-rankness. The proposed method is evaluated both ex vivo and in vivo, and is compared to methods using either a low-rank or sparsity constraint alone. Results: Compared to using a low-rank or sparsity constraint alone, the proposed method preserves more accurate helix angle features, the transmural continuum across the myocardium wall, and mean diffusivity at higher acceleration, while yielding significantly lower bias and higher intraclass correlation coefficient. Conclusion: Low-rankness and compressed sensing together facilitate acceleration for both ex vivo and in vivo CDTI, improving reconstruction accuracy compared to employing either constraint alone. Significance: Compared to previous methods for accelerating CDTI, the proposed method has the potential to reach higher acceleration while preserving myofiber architecture features which may allow more spatial coverage, higher spatial resolution and shorter temporal footprint in the future.
评论: 11 pages, 16 figures, published on IEEE Transactions on Biomedical Engineering
主题: 信号处理 (eess.SP)
引用方式: arXiv:1801.03525 [eess.SP]
  (或者 arXiv:1801.03525v1 [eess.SP] 对于此版本)
  https://doi.org/10.48550/arXiv.1801.03525
期刊参考: S. Ma et al., "Accelerated Cardiac Diffusion Tensor Imaging Using Joint Low-Rank and Sparsity Constraints," in IEEE Transactions on Biomedical Engineering, 2017, vol. PP, no. 99, pp. 1-1
相关 DOI: https://doi.org/10.1109/TBME.2017.2787111

提交历史

来自:Sen Ma
[v1] 2018年1月10日 星期三 19:32:48 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

eess.SP
< 上一篇   |   下一篇 >
最新 | 近期 | 2018-01
切换浏览方式为:
eess

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站