跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

物理学 > 医学物理

arXiv:1801.09533 (physics)
[提交于 2018年1月19日]

标题:Statistical Image Reconstruction Using Mixed Poisson-Gaussian Noise Model for X-Ray CT

作者:Qiaoqiao Ding, Yong Long, Xiaoqun Zhang, Jeffrey A. Fessler
查看论文《Statistical Image Reconstruction Using Mixed Poisson-Gaussian Noise Model for X-Ray CT》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Statistical image reconstruction (SIR) methods for X-ray CT produce high-quality and accurate images, while greatly reducing patient exposure to radiation. When further reducing X-ray dose to an ultra-low level by lowering the tube current, photon starvation happens and electronic noise starts to dominate, which introduces negative or zero values into the raw measurements. These non-positive values pose challenges to post-log SIR methods that require taking the logarithm of the raw data, and causes artifacts in the reconstructed images if simple correction methods are used to process these non-positive raw measurements. The raw data at ultra-low dose deviates significantly from Poisson or shifted Poisson statistics for pre-log data and from Gaussian statistics for post-log data. This paper proposes a novel SIR method called MPG (mixed Poisson-Gaussian). MPG models the raw noisy measurements using a mixed Poisson-Gaussian distribution that accounts for both the quantum noise and electronic noise. MPG is able to directly use the negative and zero values in raw data without any pre-processing. MPG cost function contains a reweighted least square data-fit term, an edge preserving regularization term and a non-negativity constraint term. We use Alternating Direction Method of Multipliers (ADMM) to separate the MPG optimization problem into several sub-problems that are easier to solve. Our results on 3D simulated cone-beam data set and synthetic helical data set generated from clinical data indicate that the proposed MPG method reduces noise and decreases bias in the reconstructed images, comparing with the conventional filtered back projection (FBP), penalized weighted least-square (PWLS) and shift Poisson (SP) method for ultra-low dose CT (ULDCT) imaging.
评论: 11 pages,6 figures
主题: 医学物理 (physics.med-ph); 数值分析 (cs.NA); 数值分析 (math.NA)
引用方式: arXiv:1801.09533 [physics.med-ph]
  (或者 arXiv:1801.09533v1 [physics.med-ph] 对于此版本)
  https://doi.org/10.48550/arXiv.1801.09533

提交历史

来自:Qiaoqiao Ding Ms.
[v1] 2018年1月19日 星期五 05:41:39 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics.med-ph
< 上一篇   |   下一篇 >
最新 | 近期 | 2018-01
切换浏览方式为:
physics
cs.NA
math.NA

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站