物理学 > 原子物理
[提交于 2018年2月13日]
标题:Analysis of Short-Term Stability of Miniature 171Yb+ Buffer Gas Cooled Trapped Ion Clock
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读摘要:We demonstrate an improvement in short-term stability by a factor of 10 over a previous generation miniature buffer gas cooled trapped ion clock. We describe the enhancement to detection SNR that has enabled this improvement, the method of clock operation, and the measurement of clock short-term stability. Additionally, we numerically investigate the magnitude of the Dick effect in our pulsed ion clock.
提交历史
来自:David Scherer[v1] 2018年2月13日 星期二 19:45:06 UTC