跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

物理学 > 仪器与探测器

arXiv:1803.02690 (physics)
[提交于 2019年5月1日]

标题:Comparison of 35 and 50 {\mu}m thin HPK UFSD after neutron irradiation up to 6*10^15 neq/cm^2

作者:Y. Zhao, N. Cartiglia, E. Estrada, Z. Galloway, C. Gee, A. Goto, Z. Luce, S. M. Mazza, F. McKinney-Martinez, R. Rodriguez, H. F. -W. Sadrozinski, A. Seiden V. Cindro, G. Kramberger, I. Mandić, M. Mikuž, M. Zavrtanik
查看论文《Comparison of 35 and 50 {\mu}m thin HPK UFSD after neutron irradiation up to 6*10^15 neq/cm^2》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:We report results from the testing of 35 {\mu}m thick Ultra-Fast Silicon Detectors (UFSD produced by Hamamatsu Photonics (HPK), Japan and the comparison of these new results to data reported before on 50 {\mu}m thick UFSD produced by HPK. The 35 {\mu}m thick sensors were irradiated with neutrons to fluences of 0, 1*10^14, 1*10^15, 3*10^15, 6*10^15 neq/cm^2. The sensors were tested pre-irradiation and post-irradiation with minimum ionizing particles (MIPs) from a 90Sr \b{eta}-source. The leakage current, capacitance, internal gain and the timing resolution were measured as a function of bias voltage at -20C and -27C. The timing resolution was extracted from the time difference with a second calibrated UFSD in coincidence, using the constant fraction method for both. Within the fluence range measured, the advantage of the 35 {\mu}m thick UFSD in timing accuracy, bias voltage and power can be established.
评论: 9 pages, 9 figures, HSTD11 Okinawa. arXiv admin note: text overlap with arXiv:1707.04961
主题: 仪器与探测器 (physics.ins-det); 高能物理 - 实验 (hep-ex)
引用方式: arXiv:1803.02690 [physics.ins-det]
  (或者 arXiv:1803.02690v1 [physics.ins-det] 对于此版本)
  https://doi.org/10.48550/arXiv.1803.02690
相关 DOI: https://doi.org/10.1016/j.nima.2018.08.040

提交历史

来自:Hartmut Sadrozinski
[v1] 2019年5月1日 星期三 00:00:00 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics.ins-det
< 上一篇   |   下一篇 >
最新 | 近期 | 2019-05
切换浏览方式为:
physics
hep-ex

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站