标题:Measurement of Dispersion of a Clinical Proton Therapy Beam

作者:Satomi Shiraishi, Michael G. Herman, Keith M. Furutani
查看论文《Measurement of Dispersion of a Clinical Proton Therapy Beam》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Purpose: To measure dispersion of a clinical proton therapy beam. Methods and Materials: The proton center at our institution uses a Hitachi PROBEAT V synchrotron that delivers beams with energies ranging from 70 to 230 MeV to five treatment rooms, four of which have gantries and one fixed beam. For this study, the magnetic field strengths of all optics in the transport line were varied to measure the dispersion of 230 MeV beams in each of the four gantry rooms. Beam position was measured using the Spot Position Monitor (SPM), a multi-wire proportional counter (MWPC) in the nozzle approximately 0.5 meters upstream of the treatment isocenter. Measured beam positions as a function of momentum offset were fitted to a linear function to extract dispersion. In one gantry, dispersions for 70 and 140 MeV beams were also measured. Because spot position is continuously monitored during treatments and a position deviation will abort the beam delivery, the dispersion at the spot position monitor was used to set an upper limit of range uncertainty originating from momentum deviation. When dispersion was approximately zero, dose rate measurements were used to set an upper limit of momentum deviation that could reach the patient. Results: Dispersion was 0.45 m, 0.48 m and 0.30 m for 70 MeV, 140 MeV, and 230 MeV beams in a gantry, respectively, corresponding to 0.3 mm, 1.0 mm and 3.5 mm maximum range uncertainty during treatments. For 230 MeV beams, dispersion ranged from 0 to 0.73 m across the four gantries, corresponding to the upper limits of range uncertainty due to momentum deviation of 1.4 to 6.2 mm (0.4 to 1.9% in fractional range uncertainty). Conclusions: The measured dispersion was both energy- and gantry-dependent and ranged from 0 to 0.73 m.
评论: Submitted to Medical Physics. Corresponding Author: [email protected]
主题: 医学物理 (physics.med-ph); 仪器与探测器 (physics.ins-det)
引用方式: arXiv:1805.00080 [physics.med-ph]
  (或者 arXiv:1805.00080v1 [physics.med-ph] 对于此版本)
  https://doi.org/10.48550/arXiv.1805.00080

提交历史

来自:Keith Furutani
[v1] 2018年4月30日 星期一 20:05:56 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics.med-ph
< 上一篇   |   下一篇 >
最新 | 近期 | 2018-04
切换浏览方式为:
physics
physics.ins-det

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站