物理学 > 等离子体物理
[提交于 2018年5月19日]
标题:Optimization of Neon Soft X-ray Emission in Low Energy Dense Plasma Focus Device
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读摘要:The Lee model code is used in numerical experiments for characterizing and optimizing neon soft X-ray (Ysxr) yield of UNU/ICTP PFF machine operated at 14 kV and 30 micro F. The neon Ysxr yield of the dense plasma focus device is enhanced by reducing static inductance (L0) and anode length (z0) along with increasing anode radius (a) and cathode radius (b), keeping their ratio (c = b/a) constant at 3.368. At the optimum combination of the electrodes geometry and static inductance, the maximum computed value of neon Ysxr yield is 63.61 J at operating pressure 3.3 Torr with corresponding X-ray yield efficiency 2.16%, while the end axial speed becomes 6.42 cm/s. This value of neon Ysxr yield is twelve to thirteen times higher than the measured value (5.4 J) at 3.0 Torr. It is also found that this neon Ysxr yield is improved around seven times from previously computed value (9.5 J) at 3.5 Torr for optimum anode configuration of this machine. Our obtained results of neon Ysxr yield are also compared with the computed results of AECS-PF2 machine operated at 15 kV and 25 micro F and is found that our results are about three times better than that from the optimized AECS-PF2 at L0 = 15 nH.
提交历史
来自:M. A. Malek[v1] 2018年5月19日 星期六 04:47:23 UTC