标题:Garnet Ring Measurements For The Fermilab Booster 2nd Harmonic Cavity
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读摘要:A perpendicularly biased tuneable 2nd harmonic cavity is being constructed for use in the Fermilab Booster. The cavity's tuner uses National Magnetics AL800 garnet as the tuning media. For quality control, the magnetic properties of the material and the uniformity of the properties within the tuner must be assessed. We describe two tests which are performed on the rings and on their corresponding witness samples.
提交历史
来自:Madrak Plant, Robyn L.[v1] 2018年6月14日 星期四 19:29:13 UTC