标题:Simultaneous Motion Monitoring and Truth-In-Delivery Analysis Imaging Framework for MR-guided Radiotherapy

作者:Nikolai J. Mickevicius, Xinfeng Chen, Zachary Boyd, Hannah J. Lee, Geoffrey S. Ibbott, Eric S. Paulson
查看论文《Simultaneous Motion Monitoring and Truth-In-Delivery Analysis Imaging Framework for MR-guided Radiotherapy》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Intrafraction motion can play a pivotal role in the success of abdominal and thoracic radiation therapy. Hybrid magnetic resonance-guided radiotherapy systems have the potential to control for intrafraction motion. Recently, we introduced an MRI sequence capable of acquiring real-time cine imaging in two orthogonal planes (SOPI). We extend SOPI here to permit dynamic updating of slice positions in one plane while keeping the other plane position fixed. In this implementation, cine images from the static plane are used for motion monitoring and as image navigators to sort stepped images in the other plane, producing dynamic 4D image volumes for use in dose reconstruction. A custom 3D-printed target filled with radiochromic FXG gel was interfaced to a dynamic motion phantom. 4D-SOPI was acquired in a dynamic motion phantom driven by an actual patient respiratory waveform displaying amplitude/frequency variations and drifting and in a healthy volunteer. Unique 4D-MRI epochs were reconstructed from a time series of phantom motion. Dose from a static 4cmx15cm field was calculated on each 4D respiratory phase bin and epoch image, scaled by the time spent in each bin, and then rigidly accumulated. The phantom was then positioned on an Elekta MR Linac and irradiated while moving. Following irradiation, actual dose deposited to the FXG gel was determined by applying a R1 versus dose calibration curve to R1 maps of the phantom. The 4D-SOPI cine images produced a respiratory motion navigator that was highly correlated with the actual phantom motion (CC=0.9981). The mean difference between the accumulated and measured dose inside the target was 4.4% of the maximum prescribed dose. These results provide early validation that 4D-SOPI simultaneously enables real-time motion monitoring and truth-in-delivery analysis for integrated MR-guided radiation therapy (MR-gRT) systems.
评论: 26 pages, 12 figures, submitted to Physics in Medicine and Biology
主题: 医学物理 (physics.med-ph)
引用方式: arXiv:1806.07716 [physics.med-ph]
  (或者 arXiv:1806.07716v1 [physics.med-ph] 对于此版本)
  https://doi.org/10.48550/arXiv.1806.07716
相关 DOI: https://doi.org/10.1088/1361-6560/aaec91

提交历史

来自:Nikolai Mickevicius
[v1] 2018年6月20日 星期三 13:25:59 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics.med-ph
< 上一篇   |   下一篇 >
最新 | 近期 | 2018-06
切换浏览方式为:
physics

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站