标题:Dynamics of Insufflated Abdominal Wall Tissue for Magnetically Anchored Surgical Instruments

作者:Florence Leong, Alireza Mohammadi, Vijay Rajagopal, Ying Tan, Dhan Thiruchelvam, Pietro Valdastri, Denny Oetomo
查看论文《Dynamics of Insufflated Abdominal Wall Tissue for Magnetically Anchored Surgical Instruments》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Magnetically-anchored surgical devices have recently gained attention in abdominal surgery, with the use of magnets to anchor surgical devices onto the insufflated abdominal wall. These anchors have been used to secure passive and active devices, where active device such as robotic manipulators produce motions that would excite the dynamics of the non-rigid abdominal wall. Hence, there is a need to investigate the mechanical dynamics of the abdominal wall tissue in insufflated state, combined with magnetic anchoring, specifically its response to mechanical excitations and the expected disturbances to the operation of the anchored devices. In this paper, loading and unloading tests are performed on a corresponding porcine specimen for dynamics identification. The experiment setup was constructed to emulate the insufflated state of the abdomen with the magnetically anchored mechanism. The tissue responses during unloading are captured and approximated with a general numerical model, which is in turn used for the dynamic analysis of the tissue using Bode plot. The results showed that in such stretched and compressed state, the steady state displacement of the tissue is approximately zero. The maximum transient error was found to be 1mm in displacement using a high magnetic anchoring force. Significant attenuation of the disturbances due to the high stiffness and damping of the abdominal wall, was observed from 100rad/s in the frequency response. If a robotic manipulator was attached to the anchoring device, the typical operating frequency of movements would still produce unattenuated disturbances. It is expected that some error compensation through suitable control strategies is required. These outcomes establish the basis for the controller design and the design specification of the active magnetically-anchored surgical devices for minimal disturbance impact onto the abdominal wall tissue.
评论: A 10-page journal article submitted to Journal of Medical Robotics Research (JMRR)
主题: 医学物理 (physics.med-ph)
引用方式: arXiv:1806.09067 [physics.med-ph]
  (或者 arXiv:1806.09067v1 [physics.med-ph] 对于此版本)
  https://doi.org/10.48550/arXiv.1806.09067

提交历史

来自:Florence Leong Ching Ying
[v1] 2018年6月24日 星期日 02:24:11 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics.med-ph
< 上一篇   |   下一篇 >
最新 | 近期 | 2018-06
切换浏览方式为:
physics

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站