标题:NIRS Based Bladder Volume Sensing for Patients Suffering with Neurogenic Bladder Dysfunction

作者:Prashant Gupta
查看论文《NIRS Based Bladder Volume Sensing for Patients Suffering with Neurogenic Bladder Dysfunction》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Neurogenic Bladder Dysfunction has detrimental effects on day-to-day life of millions of people. Some of the most common symptoms faced by these patients include urinary incontinence, urgency and retention. Since elevated bladder pressure due to prolonged urine storage inside bladder may have adverse impacts on patient's renal health, urologists recommend clean-intermittent catheterization (CIC) every 2 to 4 hours throughout the day to relieve bladder pressure. However, since urine production by kidneys is an intermittent process and most of these patients have limited mobility, such frequent trips to washroom can prove to be challenging. Sometimes, bladder fills to capacity before the recommended CIC time is reached causing embarrassing situation due to leakage. Hence, time-based CIC strategy is difficult to implement and has high chances of failure. As such, continence is the primary concern for most of these patients but sadly there are no practical solutions available in the market that address this concern. A real-time notification system that could give feedback to patients on when "bladder is almost-full" could help these patients to better plan their bathroom trips. This work explores the feasibility of using a near infrared-light based wearable, non-invasive spectroscopy technique that can sense amount of urine present inside the bladder and give details on developing a bladder state estimation device. We present preliminary results by testing our device on optical phantoms and performing ex vivo measurements on porcine bladder and intestines. We later explored the possibility of using the device on human subjects, after study was approved by the UC Davis Institution Review Board (IRB).
评论: Master's Thesis, University of California, Davis; 58 pages, 24 figures
主题: 信号处理 (eess.SP); 医学物理 (physics.med-ph)
引用方式: arXiv:1807.03145 [eess.SP]
  (或者 arXiv:1807.03145v1 [eess.SP] 对于此版本)
  https://doi.org/10.48550/arXiv.1807.03145

提交历史

来自:Prashant Gupta
[v1] 2018年7月10日 星期二 00:00:00 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

eess.SP
< 上一篇   |   下一篇 >
最新 | 近期 | 2018-07
切换浏览方式为:
eess
physics.med-ph

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站