标题:Optical verification and in-vitro characterization of two commercially available acoustic bubble counters for cardiopulmonary bypass systems

作者:Tim Segers, Marco C. Stehouwer, Filip M. J. J. de Somer, Bastian A. de Mol, Michel Versluis
查看论文《Optical verification and in-vitro characterization of two commercially available acoustic bubble counters for cardiopulmonary bypass systems》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Gaseous microemboli (GME) introduced during cardiac surgery are considered as a potential source of morbidity, which has driven the development of the first bubble counters. Two new generation bubble counters claim correct sizing and counting of GME. This in-vitro study aims to validate the accuracy of two bubble counters using monodisperse bubbles in a highly controlled setting at low GME concentrations. Monodisperse GME with a radius of 43 {\mu}m were produced in a microfluidic chip. Directly after their formation, they were injected one-by-one into the BCC200 and the EDAC sensors. GME size and count were optically verified using high-speed imaging. During best-case scenarios or low GME concentrations of GME with a size of 43 {\mu}m in radius in an in-vitro setup, the BCC200 overestimates GME size by a factor of 2 to 3 while the EDAC underestimates the average GME size by at least a factor of two. The BCC200 overestimates the GME concentration by approximately 20% while the EDAC overestimates the concentration by nearly one order of magnitude. Nevertheless, the calculated total GME volume is only over-predicted by a factor 2 since the EDAC underestimates the actual GME size. For the BCC200, the total GME volume was over-predicted by 25 times due to the over-estimation of GME size. The measured errors in the absolute sizing/counting of GME do not imply that all results obtained using the bubble counters are insignificant or invalid. A relative change in bubble size or bubble concentration can accurately be measured. However, care must be taken in the interpretation of the results and their absolute values. Moreover, the devices cannot be used interchangeably when reporting GME activity. Nevertheless, both devices can be used to study the relative air removal characteristics of CPB components or for the quantitative monitoring of GME production during CPB interventions.
主题: 医学物理 (physics.med-ph)
引用方式: arXiv:1807.08946 [physics.med-ph]
  (或者 arXiv:1807.08946v1 [physics.med-ph] 对于此版本)
  https://doi.org/10.48550/arXiv.1807.08946
期刊参考: Perfusion, 2018, 33(1), 16-24
相关 DOI: https://doi.org/10.1177/0267659117722595

提交历史

来自:Tim Segers
[v1] 2018年7月24日 星期二 08:09:42 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics.med-ph
< 上一篇   |   下一篇 >
最新 | 近期 | 2018-07
切换浏览方式为:
physics

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站