计算机科学 > 新兴技术
[提交于 2018年7月24日]
标题:On complexity of post-processing in analyzing GATE-driven X-ray spectrum
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读摘要:Computed Tomography (CT) imaging is one of the most influential diagnostic methods. In clinical reconstruction, an effective energy is used instead of total X-ray spectrum. This approximation causes an accuracy decline. To increase the contrast, single source or dual source dual energy CT can be used to reach optimal values of tissue differentiation. However, these infrastructures are still at the laboratory level, and their safeties for patients are still yet to mature. Therefore, computer modelling of DECT could be used. We propose a novel post-processing approach for converting a total X-ray spectrum into irregular intervals of quantized energy. We simulate a phantom in GATE/GEANT4 and irradiate it based on CT configuration. Inverse Radon transform is applied to the acquired sinogram to construct the Pixel-based Attenuation Matrix (PAM). To construct images represented by each interval, water attenuation coefficient of the interval is extracted from NIST and used in the Hounsfield unit (HU) scale in conjunction with PAM. The CT image is modified by using of an associated normalized photon flux and calculated HU corresponding to the interval. We demonstrate the proposed method efficiency via complexity analysis, using absolute and relative complexities, entropy measures, Kolmogorov complexity, morphological richness, and quantitative segmentation criteria associated with standard fuzzy C-means. The irregularity of the modified CT images decreases over the simulated ones.
提交历史
来自:Andrew Adamatzky[v1] 2018年7月24日 星期二 12:25:01 UTC