跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

物理学 > 光学

arXiv:1809.02175 (physics)
[提交于 2023年7月10日]

标题:Optical frequency comb photoacoustic spectroscopy

作者:Ibrahim Sadiek, Tommi Mikkonen, Markku Vainio, Juha Toivonen, Aleksandra Foltynowicz
查看论文《Optical frequency comb photoacoustic spectroscopy》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:We report the first photoacoustic detection scheme using an optical frequency comb - the optical frequency comb photoacoustic spectroscopy (OFC-PAS). OFC-PAS combines the broad spectral coverage and the high resolution of OFCs with the small sample volume of cantilever-enhanced PA detection. In OFC-PAS, a Fourier transform spectrometer (FTS) is used to modulate the intensity of the exciting comb source at a frequency determined by its scanning speed. One of the FTS outputs is directed to the PA cell and the other is measured simultaneously with a photodiode and used to normalize the PA signal. The cantilever-enhanced PA detector operates in a non-resonant mode, enabling detection of broadband frequency response. The broadband and the high-resolution capabilities of OFC-PAS are demonstrated by measuring the rovibrational spectra of the fundamental C-H stretch band of CH${_4}$, with no instrumental line shape distortions, at total pressures of 1000 mbar, 650 mbar, and 400 mbar. In this first demonstration, a spectral resolution two orders of magnitude higher than previously reported with broadband PAS is obtained, limited by the pressure broadening. A limit of detection of 0.8 ppm of methane in N${_2}$ is accomplished in a single interferogram measurement (200 s measurement time, 1000 MHz resolution, 1000 mbar total pressure) for an exciting power spectral density of 42 {\mu}W/cm${^{-1}}$. A normalized noise equivalent absorption of 8x10${^{-10}}$ W cm${^{-1}}$ Hz${^{-1/2}}$ is obtained, which is only a factor of three higher than the best reported with PAS based on continuous wave lasers. A wide dynamic range of up to four orders of magnitude and a very good linearity (limited by the Beer-Lambert law) over two orders of magnitude are realized. OFC-PAS extends the capability of optical sensors for multispecies trace gas analysis in small sample volume with high resolution and selectivity.
主题: 光学 (physics.optics); 仪器与探测器 (physics.ins-det)
引用方式: arXiv:1809.02175 [physics.optics]
  (或者 arXiv:1809.02175v1 [physics.optics] 对于此版本)
  https://doi.org/10.48550/arXiv.1809.02175
期刊参考: Phys. Chem. Chem. Phys. 20, 27849-27855 (2018)
相关 DOI: https://doi.org/10.1039/C8CP05666H

提交历史

来自:Aleksandra Foltynowicz
[v1] 2023年7月10日 星期一 00:00:00 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics.optics
< 上一篇   |   下一篇 >
最新 | 近期 | 2023-07
切换浏览方式为:
physics
physics.ins-det

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站