跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

物理学 > 医学物理

arXiv:1811.03665 (physics)
[提交于 2019年9月4日]

标题:A conceptual study on real-time adaptive radiation therapy optimization through ultra-fast beamlet control

作者:Rodney D. Wiersma, Xinmin Liu
查看论文《A conceptual study on real-time adaptive radiation therapy optimization through ultra-fast beamlet control》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:A central problem in the field of radiation therapy (RT) is how to optimally deliver dose to a patient in a way that fully accounts for anatomical position changes over time. As current RT is a static process, where beam intensities are calculated before the start of treatment, anatomical deviations can result in poor dose conformity. To overcome these limitations, we present a simulation study on a fully dynamic real-time adaptive radiation therapy (RT-ART) optimization approach that uses ultra-fast beamlet control to dynamically adapt to patient motion in real-time. A virtual RT-ART machine was simulated with a rapidly rotating linear accelerator (LINAC) source (60 RPM) and a binary 1D multi-leaf collimator (MLC) operating at 100 Hz. If the real-time tracked target motion exceeded a predefined threshold, a time dependent objective function was solved using fast optimization methods to calculate new beamlet intensities that were then delivered to the patient. To evaluate the approach, system response was analyzed for patient derived continuous drift, step-like, and periodic intra-fractional motion. For each motion type investigated, the RT-ART method was compared against the ideal case with no patient motion (static case) as well as to the case without the use RT-ART. In all cases, isodose lines and dose-volume-histograms (DVH) showed that RT-ART plan quality was approximately the same as the static case, and considerably better than the no RT-ART case. The RT-ART optimization framework has the potential to optimally deliver dose to a patient in a way that fully accounts for anatomical changes due to motion. With continued advances in real-time patient motion tracking and fast computational processes, there is significant potential for the RT-ART optimization process to be realized on next generation RT machines.
主题: 医学物理 (physics.med-ph)
引用方式: arXiv:1811.03665 [physics.med-ph]
  (或者 arXiv:1811.03665v1 [physics.med-ph] 对于此版本)
  https://doi.org/10.48550/arXiv.1811.03665
期刊参考: https://iopscience.iop.org/article/10.1088/2057-1976/ab3ba9

提交历史

来自:Rodney Wiersma
[v1] 2019年9月4日 星期三 00:00:00 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics.med-ph
< 上一篇   |   下一篇 >
最新 | 近期 | 2019-09
切换浏览方式为:
physics

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站