跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

电气工程与系统科学 > 信号处理

arXiv:1811.06541 (eess)
[提交于 2018年11月14日]

标题:Mathematical Modeling of Arterial Blood Pressure Using Photo-Plethysmography Signal in Breath-hold Maneuver

作者:Armin Soltan Zadi, Raichel M. Alex, Rong Zhang, Donald E. Watenpaugh, Khosrow Behbehani
查看论文《Mathematical Modeling of Arterial Blood Pressure Using Photo-Plethysmography Signal in Breath-hold Maneuver》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Recent research has shown that each apnea episode results in a significant rise in the beat-to-beat blood pressure and by a drop to the pre-episode levels when patient resumes normal breathing. While the physiological implications of these repetitive and significant oscillations are still unknown, it is of interest to quantify them. Since current array of instruments deployed for polysomnography studies does not include beat-to-beat measurement of blood pressure, but includes oximetry, it is both of clinical interest to estimate the magnitude of BP oscillations from the photoplethysmography (PPG) signal that is readily available from sleep lab oximeters. We have investigated a new method for continuous estimation of systolic (SBP), diastolic (DBP), and mean (MBP) blood pressure waveforms from PPG. Peaks and troughs of PPG waveform are used as input to a 5th order autoregressive moving average model to construct estimates of SBP, DBP, and MBP waveforms. Since breath hold maneuvers are shown to simulate apnea episodes faithfully, we evaluated the performance of the proposed method in 7 subjects (4 F; 32+-4 yrs., BMI 24.57+-3.87 kg/m2) in supine position doing 5 breath maneuvers with 90s of normal breathing between them. The modeling error ranges were (all units are in mmHg) -0.88+-4.87 to -2.19+-5.73 (SBP); 0.29+-2.39 to -0.97+-3.83 (DBP); and -0.42+-2.64 to -1.17+-3.82 (MBP). The cross validation error ranges were 0.28+-6.45 to -1.74+-6.55 (SBP); 0.09+-3.37 to -0.97+-3.67 (DBP); and 0.33+-4.34 to -0.87+-4.42 (MBP). The level of estimation error in, as measured by the root mean squared of the model residuals, was less than 7 mmHg
评论: 4 pages, published in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
主题: 信号处理 (eess.SP); 计算工程、金融与科学 (cs.CE)
引用方式: arXiv:1811.06541 [eess.SP]
  (或者 arXiv:1811.06541v1 [eess.SP] 对于此版本)
  https://doi.org/10.48550/arXiv.1811.06541
期刊参考: pages 2711-2714 (publisher:IEEE), 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), October 2018
相关 DOI: https://doi.org/10.1109/EMBC.2018.8512776

提交历史

来自:Armin Soltan Zadi
[v1] 2018年11月14日 星期三 22:38:00 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

eess.SP
< 上一篇   |   下一篇 >
最新 | 近期 | 2018-11
切换浏览方式为:
eess
cs.CE

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站