跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

定量生物学 > 组织与器官

arXiv:1811.11443 (q-bio)
[提交于 2018年11月28日]

标题:Optical probe pressure effects on cutaneous blood flow

作者:Irina A. Mizeva, Elena V. Potapova, Viktor V. Dremin, Evgeny A. Zherebtsov, Mikhail A. Mezentsev, Valerii V. Shupletsov, Andrey V. Dunaev
查看论文《Optical probe pressure effects on cutaneous blood flow》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:The variation of blood flow characteristics caused by the probe pressure during noninvasive studies is of particular interest within the context of fundamental and applied research. It has been shown previously that the weak local pressure induces vasodilation, whereas the increased pressure is able to stop the blood flow in the compressed area, as well as to significantly change optical signals. The blood flow oscillations measured by laser Doppler flowmetry (LDF) characterize the functional state of the microvascular system and can be used for noninvasive diagnostics of its abnormality. This study was intended to identify the patterns of the relationship between the oscillating components of blood flow registered by the LDF method under different levels of pressure applied to an optical fiber probe. For this purpose we have developed an original optical probe capable of regulating the applied pressure. The developed protocol included six sequential records of the blood perfusion at pressure within the 0 to 200 mmHg range with unloading at the last stage. Using wavelet analyses, we traced the variation of energy of oscillations for these records in five frequency bands associated with different vascular tone regulation mechanisms. Six young volunteers of the same age (three males and three females) were included in this preliminary study and the protocol was repeated five times in each volunteer. Totally 30 LDF records were available for the analyses. As expected, the LDF signal increases at weak pressure (30 mmHg) and decreases at increased pressure. The statistically stable amplification of endothelial associated blood flow oscillations under the 90 mmHg pressure allowed us to put forward a hypothesis that the endothelial activity increases. The possible causes of this phenomenon are discussed.
评论: 8 pages, 6 figures
主题: 组织与器官 (q-bio.TO)
引用方式: arXiv:1811.11443 [q-bio.TO]
  (或者 arXiv:1811.11443v1 [q-bio.TO] 对于此版本)
  https://doi.org/10.48550/arXiv.1811.11443
相关 DOI: https://doi.org/10.3233/CH-180459

提交历史

来自:Irina Mizeva
[v1] 2018年11月28日 星期三 08:38:59 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

q-bio.TO
< 上一篇   |   下一篇 >
最新 | 近期 | 2018-11
切换浏览方式为:
q-bio

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站