标题:Uncertainty evalutation through data modelling for dimensional nanoscale measurements

作者:J. Pétry, B. De Boeck, N. Sebaihi, M. Coenegrachts, T. Caebergs, M. Dobre
查看论文《Uncertainty evalutation through data modelling for dimensional nanoscale measurements》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:A major bottleneck in nanoparticle measurements is the lack of comparability. Comparability of measurement results is obtained by metrological traceability, which is obtained by calibration. In the present work the calibration of dimensional nanoparticle measurements is performed through the construction of a calibration curve by comparison of measured reference standards to their certified value. Subsequently, a general approach is proposed to perform a measurement uncertainty evaluation for a measured quantity when no comprehensive physical model is available, by statistically modelling appropriately selected measurement data. The experimental data is collected so that the influence of relevant parameters can be assessed by fitting a mixed model to the data. Furthermore, this model allows to generate a probability density function (PDF) for the concerned measured quantity. Applying this methodology to dimensional nanoparticle measurements leads to a PDF for a measured dimensional quantity of the nanoparticles. A PDF for the measurand, which is the certified counterpart of that measured dimensional quantity, can then be extracted by reporting a PDF for the measured dimensional quantity on the calibration curve. The PDF for the measurand grasps its total measurement uncertainty. Working in a fully Bayesian framework is natural due to the instrinsic caracter of the quantity of interest: the distribution of size rather than the size of one single particle. The developed methodology is applied to the particular case where dimensional nanoparticle measurements are performed using an atomic force microscope (AFM). The reference standards used to build a calibration curve are nano-gratings with step heights covering the application range of the calibration curve.
主题: 应用 (stat.AP)
引用方式: arXiv:1812.09157 [stat.AP]
  (或者 arXiv:1812.09157v1 [stat.AP] 对于此版本)
  https://doi.org/10.48550/arXiv.1812.09157

提交历史

来自:Jasmine Petry
[v1] 2018年12月21日 星期五 14:48:14 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

stat.AP
< 上一篇   |   下一篇 >
最新 | 近期 | 2018-12
切换浏览方式为:
stat

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站