跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

电气工程与系统科学 > 图像与视频处理

arXiv:1903.03349 (eess)
[提交于 2020年4月3日]

标题:Computer aided detection of tuberculosis on chest radiographs: An evaluation of the CAD4TB v6 system

作者:Keelin Murphy, Shifa Salman Habib, Syed Mohammad Asad Zaidi, Saira Khowaja, Aamir Khan, Jaime Melendez, Ernst T. Scholten, Farhan Amad, Steven Schalekamp, Maurits Verhagen, Rick H. H. M. Philipsen, Annet Meijers, Bram van Ginneken
查看论文《Computer aided detection of tuberculosis on chest radiographs: An evaluation of the CAD4TB v6 system》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:There is a growing interest in the automated analysis of chest X-Ray (CXR) as a sensitive and inexpensive means of screening susceptible populations for pulmonary tuberculosis. In this work we evaluate the latest version of CAD4TB, a commercial software platform designed for this purpose. Version 6 of CAD4TB was released in 2018 and is here tested on a fully independent dataset of 5565 CXR images with GeneXpert (Xpert) sputum test results available (854 Xpert positive subjects). A subset of 500 subjects (50% Xpert positive) was reviewed and annotated by 5 expert observers independently to obtain a radiological reference standard. The latest version of CAD4TB is found to outperform all previous versions in terms of area under receiver operating curve (ROC) with respect to both Xpert and radiological reference standards. Improvements with respect to Xpert are most apparent at high sensitivity levels with a specificity of 76% obtained at a fixed 90% sensitivity. When compared with the radiological reference standard, CAD4TB v6 also outperformed previous versions by a considerable margin and achieved 98% specificity at the 90% sensitivity setting. No substantial difference was found between the performance of CAD4TB v6 and any of the various expert observers against the Xpert reference standard. A cost and efficiency analysis on this dataset demonstrates that in a standard clinical situation, operating at 90% sensitivity, users of CAD4TB v6 can process 132 subjects per day at n average cost per screen of \$5.95 per subject, while users of version 3 process only 85 subjects per day at a cost of \$8.38 per subject. At all tested operating points version 6 is shown to be more efficient and cost effective than any other version.
评论: Published in Scientific Reports
主题: 图像与视频处理 (eess.IV); 计算机视觉与模式识别 (cs.CV)
引用方式: arXiv:1903.03349 [eess.IV]
  (或者 arXiv:1903.03349v1 [eess.IV] 对于此版本)
  https://doi.org/10.48550/arXiv.1903.03349
期刊参考: Scientific Reports 10, 5492 (2020)
相关 DOI: https://doi.org/10.1038/s41598-020-62148-y

提交历史

来自:Keelin Murphy
[v1] 2020年4月3日 星期五 00:00:00 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

eess.IV
< 上一篇   |   下一篇 >
最新 | 近期 | 2020-04
切换浏览方式为:
eess
cs.CV

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站