跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

物理学 > 医学物理

arXiv:1904.03704 (physics)
[提交于 2019年4月9日]

标题:Flexible and Comprehensive Patient-Specific Mitral Valve Silicone Models with Chordae Tendinae Made From 3D-Printable Molds

作者:Sandy Engelhardt, Simon Sauerzapf, Bernhard Preim, Matthias Karck, Ivo Wolf, Raffaele De Simone
查看论文《Flexible and Comprehensive Patient-Specific Mitral Valve Silicone Models with Chordae Tendinae Made From 3D-Printable Molds》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Given the multitude of challenges surgeons face during mitral valve repair surgery, they should have a high confidence in handling of instruments and in the application of surgical techniques before they enter the operating room. Unfortunately, opportunities for surgical training of minimally-invasive repair are very limited, leading to a situation where most surgeons undergo a steep learning curve while operating the first patients. In order to provide a realistic tool for surgical training, a commercial simulator was augmented by flexible patient-specific mitral valve replica. In an elaborated production pipeline, finalized after many optimization cycles, models were segmented from 3D ultrasound and then 3D-printable molds were computed automatically and printed in rigid material, the lower part being water-soluble. After silicone injection, the silicone model was dissolved from the mold and anchored in the simulator. To our knowledge, our models are the first to comprise the full mitral valve apparatus, i.e. the annulus, leaflets, chordae tendineae and papillary muscles. Nine different valve molds were automatically created according to the proposed workflow (seven prolapsed valves and two valves with functional mitral insufficiency). From these mold geometries, 16 replica were manufactured. A material test revealed that Ecoflex\textsuperscript{TM} 00-30 is the most suitable material for leaflet-mimicking tissue out of seven mixtures. Production time was around 36h per valve. Twelve surgeons performed various surgical techniques, e.g. annuloplasty, neo-chordae implantation, triangular leaflet resection and assessed the realism of the valves very positively. The standardized production process guarantees a high anatomical recapitulation of the silicone valves to the segmented models and the ultrasound data...
评论: Accepted for IJCARS Special Issue IPCAI 2019 (Information Processing in Computer-Assisted Interventions)
主题: 医学物理 (physics.med-ph); 计算机与社会 (cs.CY)
引用方式: arXiv:1904.03704 [physics.med-ph]
  (或者 arXiv:1904.03704v1 [physics.med-ph] 对于此版本)
  https://doi.org/10.48550/arXiv.1904.03704
相关 DOI: https://doi.org/10.1007/s11548-019-01971-9

提交历史

来自:Sandy Engelhardt
[v1] 2019年4月9日 星期二 00:00:00 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics.med-ph
< 上一篇   |   下一篇 >
最新 | 近期 | 2019-04
切换浏览方式为:
physics
cs.CY

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站