跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

计算机科学 > 计算机视觉与模式识别

arXiv:1906.01272 (cs)
[提交于 2019年6月5日]

标题:Evaluation of an AI system for the automated detection of glaucoma from stereoscopic optic disc photographs: the European Optic Disc Assessment Study

作者:Thomas W. Rogers, Nicolas Jaccard, Francis Carbonaro, Hans G. Lemij, Koenraad A. Vermeer, Nicolaas J. Reus, Sameer Trikha
查看论文《Evaluation of an AI system for the automated detection of glaucoma from stereoscopic optic disc photographs: the European Optic Disc Assessment Study》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Objectives: To evaluate the performance of a deep learning based Artificial Intelligence (AI) software for detection of glaucoma from stereoscopic optic disc photographs, and to compare this performance to the performance of a large cohort of ophthalmologists and optometrists. Methods: A retrospective study evaluating the diagnostic performance of an AI software (Pegasus v1.0, Visulytix Ltd., London UK) and comparing it to that of 243 European ophthalmologists and 208 British optometrists, as determined in previous studies, for the detection of glaucomatous optic neuropathy from 94 scanned stereoscopic photographic slides scanned into digital format. Results: Pegasus was able to detect glaucomatous optic neuropathy with an accuracy of 83.4% (95% CI: 77.5-89.2). This is comparable to an average ophthalmologist accuracy of 80.5% (95% CI: 67.2-93.8) and average optometrist accuracy of 80% (95% CI: 67-88) on the same images. In addition, the AI system had an intra-observer agreement (Cohen's Kappa, $\kappa$) of 0.74 (95% CI: 0.63-0.85), compared to 0.70 (range: -0.13-1.00; 95% CI: 0.67-0.73) and 0.71 (range: 0.08-1.00) for ophthalmologists and optometrists, respectively. There was no statistically significant difference between the performance of the deep learning system and ophthalmologists or optometrists. There was no statistically significant difference between the performance of the deep learning system and ophthalmologists or optometrists. Conclusion: The AI system obtained a diagnostic performance and repeatability comparable to that of the ophthalmologists and optometrists. We conclude that deep learning based AI systems, such as Pegasus, demonstrate significant promise in the assisted detection of glaucomatous optic neuropathy.
评论: 24 pages, 3 figures, 2 tables
主题: 计算机视觉与模式识别 (cs.CV); 图像与视频处理 (eess.IV)
引用方式: arXiv:1906.01272 [cs.CV]
  (或者 arXiv:1906.01272v1 [cs.CV] 对于此版本)
  https://doi.org/10.48550/arXiv.1906.01272

提交历史

来自:Thomas Rogers
[v1] 2019年6月5日 星期三 00:00:00 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

cs.CV
< 上一篇   |   下一篇 >
最新 | 近期 | 2019-06
切换浏览方式为:
cs
eess.IV

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站