物理学 > 仪器与探测器
[提交于 2019年8月15日]
标题:Analysis of Skin Effect in High Frequency Isolation Transformers
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读摘要:In this paper, a high frequency transformer with different conductors and winding arrangements, at presence of eddy currents and skin effect, is studied. By using different winding structures, and conductor types, such as circular, square shaped, and foil wires, the skin effect in the windings is studied and current density within the conductors at a high frequency of 20 MHz and a lower frequency of 20 kHz are investigated using finite element method (FEM) simulation. Moreover, magnetic field distribution in the transformers at 20 MHz is obtained and displayed. Also, magnetizing inductance, leakage inductance and AC winding resistance for all of the transformer types are found and compared, and frequency response for the transformers are obtained and shown. Lastly, based on the results, the skin effect increases the AC winding resistance and decreases the leakage inductance as the frequency increases. Furthermore, different winding arrangements, conductors, and transformer types show a wide range of parasitic and loss behavior, which enable the designers to compromise between various parameters in different applications, especially new fast switches such as SiC and GaN.
提交历史
来自:Mohamad Saleh Sanjarinia[v1] 2019年8月15日 星期四 01:27:39 UTC