标题:Prostate cancer inference via weakly-supervised learning using a large collection of negative MRI

作者:Ruiming Cao, Xinran Zhong, Fabien Scalzo, Steven Raman, Kyung hyun Sung
查看论文《Prostate cancer inference via weakly-supervised learning using a large collection of negative MRI》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Recent advances in medical imaging techniques have led to significant improvements in the management of prostate cancer (PCa). In particular, multi-parametric MRI (mp-MRI) continues to gain clinical acceptance as the preferred imaging technique for non-invasive detection and grading of PCa. However, the machine learning-based diagnosis systems for PCa are often constrained by the limited access to accurate lesion ground truth annotations for training. The performance of the machine learning system is highly dependable on both quality and quantity of lesion annotations associated with histopathologic findings, resulting in limited scalability and clinical validation. Here, we propose the baseline MRI model to alternatively learn the appearance of mp-MRI using radiology-confirmed negative MRI cases via weakly supervised learning. Since PCa lesions are case-specific and highly heterogeneous, it is assumed to be challenging to synthesize PCa lesions using the baseline MRI model, while it would be relatively easier to synthesize the normal appearance in mp-MRI. We then utilize the baseline MRI model to infer the pixel-wise suspiciousness of PCa by comparing the original and synthesized MRI with two distance functions. We trained and validated the baseline MRI model using 1,145 negative prostate mp-MRI scans. For evaluation, we used separated 232 mp-MRI scans, consisting of both positive and negative MRI cases. The 116 positive MRI scans were annotated by radiologists, confirmed with post-surgical whole-gland specimens. The suspiciousness map was evaluated by receiver operating characteristic (ROC) analysis for PCa lesions versus non-PCa regions classification and free-response receiver operating characteristic (FROC) analysis for PCa localization. Our proposed method achieved 0.84 area under the ROC curve and 77.0% sensitivity at one false positive per patient in FROC analysis.
评论: 6 pages, 5 figures, 2019 International Conference on Computer Vision - Visual Recognition for Medical Images Workshop
主题: 图像与视频处理 (eess.IV); 机器学习 (cs.LG); 定量方法 (q-bio.QM)
引用方式: arXiv:1910.02185 [eess.IV]
  (或者 arXiv:1910.02185v1 [eess.IV] 对于此版本)
  https://doi.org/10.48550/arXiv.1910.02185

提交历史

来自:KyungHyun Sung
[v1] 2019年10月8日 星期二 00:00:00 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

eess.IV
< 上一篇   |   下一篇 >
最新 | 近期 | 2019-10
切换浏览方式为:
eess
cs.LG
q-bio.QM

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站