[提交于 2020年5月5日]

标题:The reliability of a deep learning model in clinical out-of-distribution MRI data: a multicohort study

作者:Gustav Mårtensson, Daniel Ferreira, Tobias Granberg, Lena Cavallin, Ketil Oppedal, Alessandro Padovani, Irena Rektorova, Laura Bonanni, Matteo Pardini, Milica Kramberger, John-Paul Taylor, Jakub Hort, Jón Snædal, Jaime Kulisevsky, Frederic Blanc, Angelo Antonini, Patrizia Mecocci, Bruno Vellas, Magda Tsolaki, Iwona Kłoszewska, Hilkka Soininen, Simon Lovestone, Andrew Simmons, Dag Aarsland, Eric Westman
查看论文《The reliability of a deep learning model in clinical out-of-distribution MRI data: a multicohort study》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Deep learning (DL) methods have in recent years yielded impressive results in medical imaging, with the potential to function as clinical aid to radiologists. However, DL models in medical imaging are often trained on public research cohorts with images acquired with a single scanner or with strict protocol harmonization, which is not representative of a clinical setting. The aim of this study was to investigate how well a DL model performs in unseen clinical data sets---collected with different scanners, protocols and disease populations---and whether more heterogeneous training data improves generalization. In total, 3117 MRI scans of brains from multiple dementia research cohorts and memory clinics, that had been visually rated by a neuroradiologist according to Scheltens' scale of medial temporal atrophy (MTA), were included in this study. By training multiple versions of a convolutional neural network on different subsets of this data to predict MTA ratings, we assessed the impact of including images from a wider distribution during training had on performance in external memory clinic data. Our results showed that our model generalized well to data sets acquired with similar protocols as the training data, but substantially worse in clinical cohorts with visibly different tissue contrasts in the images. This implies that future DL studies investigating performance in out-of-distribution (OOD) MRI data need to assess multiple external cohorts for reliable results. Further, by including data from a wider range of scanners and protocols the performance improved in OOD data, which suggests that more heterogeneous training data makes the model generalize better. To conclude, this is the most comprehensive study to date investigating the domain shift in deep learning on MRI data, and we advocate rigorous evaluation of DL models on clinical data prior to being certified for deployment.
评论: 11 pages, 3 figures
主题: 医学物理 (physics.med-ph); 计算机视觉与模式识别 (cs.CV); 机器学习 (cs.LG); 图像与视频处理 (eess.IV); 定量方法 (q-bio.QM); 机器学习 (stat.ML)
引用方式: arXiv:1911.00515 [physics.med-ph]
  (或者 arXiv:1911.00515v1 [physics.med-ph] 对于此版本)
  https://doi.org/10.48550/arXiv.1911.00515
相关 DOI: https://doi.org/10.1016/j.media.2020.101714

提交历史

来自:Gustav Mårtensson
[v1] 2020年5月5日 星期二 00:00:00 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics.med-ph
< 上一篇   |   下一篇 >
最新 | 近期 | 2020-05
切换浏览方式为:
physics
cs.CV
cs.LG
eess.IV
q-bio.QM
stat.ML

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站