跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

物理学 > 医学物理

arXiv:1911.05665 (physics)
[提交于 2019年11月14日]

标题:Experimental investigation of the flow downstream of a dysfunctional bileaflet mechanical aortic valve

作者:Ahmed Darwish, Giuseppe Di Labbio, Wael Saleh, Othman Smadi, Lyes Kadem
查看论文《Experimental investigation of the flow downstream of a dysfunctional bileaflet mechanical aortic valve》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Mechanical heart valve replacement is the preferred alternative in younger patients with severe symptomatic aortic valve disease. However, thrombus and pannus formations are common complications associated with bileaflet mechanical heart valves. This leads to risks of valve leaflet dysfunction, a life threatening event. In this experimental study, we investigate, using time resolved planar particle image velocimetry, the flow characteristics in the ascending aorta in the presence of a dysfunctional bileaflet mechanical heart valve. Several configurations of leaflet dysfunction are investigated and the induced flow disturbances in terms of velocity fields, viscous energy dissipation, wall shear stress, and accumulation of viscous shear stresses are evaluated. We also explore the ability of a new set of parameters, solely based on the analysis of the normalized axial velocity profiles in the ascending aorta, to detect bileaflet mechanical heart valve dysfunction and differentiate between the different configurations tested in this study. Our results show that a bileaflet mechanical heart valve dysfunction leads to a complex spectrum of flow disturbances with each flow characteristic evaluated having its own worst case scenario in terms of dysfunction configuration. We also show that the suggested approach based on the analysis of the normalized axial velocity profiles in the ascending aorta has the potential to clearly discriminate not only between normal and dysfunctional bilealfet heart valves but also between the different leaflet dysfunction configurations. This approach could be easily implemented using phase contrast MRI to follow up patients with bileaflet mechanical heart valves.
主题: 医学物理 (physics.med-ph); 流体动力学 (physics.flu-dyn)
引用方式: arXiv:1911.05665 [physics.med-ph]
  (或者 arXiv:1911.05665v1 [physics.med-ph] 对于此版本)
  https://doi.org/10.48550/arXiv.1911.05665

提交历史

来自:Ahmed Darwish
[v1] 2019年11月14日 星期四 00:00:00 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics.med-ph
< 上一篇   |   下一篇 >
最新 | 近期 | 2019-11
切换浏览方式为:
physics
physics.flu-dyn

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站