跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

物理学 > 医学物理

arXiv:1912.05469 (physics)
[提交于 2024年5月15日]

标题:Analysis of effectiveness of thresholding in perfusion ROI detection on T2-weighted MR images with abnormal brain anatomy

作者:Svitlana Alkhimova, Svitlana Sliusar
查看论文《Analysis of effectiveness of thresholding in perfusion ROI detection on T2-weighted MR images with abnormal brain anatomy》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:The brain perfusion ROI detection being a preliminary step, designed to exclude non-brain tissues from analyzed DSC perfusion MR images. Its accuracy is considered as the key factor for delivering correct results of perfusion data analysis. Despite the large variety of algorithms developed on brain tissues segmentation, there is no one that works reliably and robustly on 2T-waited MR images of a human head with abnormal brain anatomy. Therefore, thresholding method is still the state-of-the-art technique that is widely used as a way of managing pixels involved in brain perfusion ROI. This paper presents the analysis of effectiveness of thresholding techniques in brain perfusion ROI detection on 2T-waited MR images of a human head with abnormal brain anatomy. Four threshold-based algorithms implementation are considered: according to Otsu method as global thresholding, according to Niblack method as local thresholding, thresholding in approximate anatomical brain location, and brute force thresholding. The analysis is done using comparison of qualitative maps produced from thresholded images and from the reference ones. Pearson correlation analysis showed strong positive (r was ranged from 0.7123 to 0.8518, p<0.01) and weak positive (r<0.35, p<0.01) relationship in case of conducted experiments with CBF, CBV, MTT and Tmax maps, respectively. Linear regression analysis showed at level of 95% confidence interval that maps produced from thresholded images were subject to scale and offset errors in all conducted experiments. The experimental results showed that widely used thresholding methods are an ineffective way of managing pixels involved in brain perfusion ROI. Thresholding as brain segmentation tool can lead to poor placement of perfusion ROI and, as a result, produced maps will be subject to artifacts and can cause falsely high or falsely low perfusion parameters assessment.
主题: 医学物理 (physics.med-ph); 计算机视觉与模式识别 (cs.CV); 图像与视频处理 (eess.IV)
引用方式: arXiv:1912.05469 [physics.med-ph]
  (或者 arXiv:1912.05469v1 [physics.med-ph] 对于此版本)
  https://doi.org/10.48550/arXiv.1912.05469
期刊参考: KPI Science News. - 2019. - V. 126, N. 4. - P.35-43
相关 DOI: https://doi.org/10.20535/kpi-sn.2019.4.180237

提交历史

来自:Svitlana Alkhimova
[v1] 2024年5月15日 星期三 00:00:00 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics.med-ph
< 上一篇   |   下一篇 >
最新 | 近期 | 2024-05
切换浏览方式为:
physics
cs.CV
eess.IV

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站