标题:Quantifying Cortical Bone Free Water Using short echo time (STE-MRI) at 1.5T

作者:Shahrokh Abbasi-Rad, Atena Akbari, Malakeh Malekzadeh, Mohammad Shahgholi, Hossein Arabalibeik, Hamidreza Saligheh Rad
查看论文《Quantifying Cortical Bone Free Water Using short echo time (STE-MRI) at 1.5T》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Purpose: The purpose of our study was to use Dual-TR STE-MR protocol as a clinical tool for cortical bone free water quantification at 1.5T and validate it by comparing the obtained results (MR-derived results) with dehydration results. Methods: Human studies were compliant with HIPPA and were approved by the institutional review board. Short Echo Time (STE) MR imaging with different Repetition Times (TRs) was used for quantification of cortical bone free water T1 (T1free) and concentration (\r{ho}free). The proposed strategy was compared with the dehydration technique in seven bovine cortical bone samples. The agreement between the two methods was quantified by using Bland and Altman analysis. Then we applied the technique on a cross-sectional population of thirty healthy volunteers (18F/12M) and examined the association of the biomarkers with age. Results: The mean values of \r{ho}free for bovine cortical bone specimens were quantified as 4.37% and 5.34% by using STE-MR and dehydration techniques, respectively. The Bland and Altman analysis showed good agreement between the two methods along with the suggestion of 0.99% bias between them. Strong correlations were also reported between \r{ho}free (r2 = 0.62) and T1free and age (r2 = 0.8). The reproducibility of the method, evaluated in eight subjects, yielded an intra-class correlation of 0.95. Conclusion: STE-MR imaging with dual-TR strategy is a clinical solution for quantifying cortical bone \r{ho}free and T1free.
主题: 医学物理 (physics.med-ph); 图像与视频处理 (eess.IV)
引用方式: arXiv:2002.00209 [physics.med-ph]
  (或者 arXiv:2002.00209v1 [physics.med-ph] 对于此版本)
  https://doi.org/10.48550/arXiv.2002.00209
相关 DOI: https://doi.org/10.1016/j.mri.2020.04.014

提交历史

来自:Shahrokh Abbasi-Rad
[v1] 2020年11月25日 星期三 00:00:00 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics.med-ph
< 上一篇   |   下一篇 >
最新 | 近期 | 2020-11
切换浏览方式为:
physics
eess.IV

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站