跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

电气工程与系统科学 > 图像与视频处理

arXiv:2004.04432 (eess)
[提交于 2020年9月9日]

标题:Automatic detection of acute ischemic stroke using non-contrast computed tomography and two-stage deep learning model

作者:Mizuho Nishio, Sho Koyasu, Shunjiro Noguchi, Takao Kiguchi, Kanako Nakatsu, Thai Akasaka, Hiroki Yamada, Kyo Itoh
查看论文《Automatic detection of acute ischemic stroke using non-contrast computed tomography and two-stage deep learning model》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Background and Purpose: We aimed to develop and evaluate an automatic acute ischemic stroke-related (AIS) detection system involving a two-stage deep learning model. Methods: We included 238 cases from two different institutions. AIS-related findings were annotated on each of the 238 sets of head CT images by referring to head magnetic resonance imaging (MRI) images in which an MRI examination was performed within 24 h following the CT scan. These 238 annotated cases were divided into a training set including 189 cases and test set including 49 cases. Subsequently, a two-stage deep learning detection model was constructed from the training set using the You Only Look Once v3 model and Visual Geometry Group 16 classification model. Then, the two-stage model performed the AIS detection process in the test set. To assess the detection model's results, a board-certified radiologist also evaluated the test set head CT images with and without the aid of the detection model. The sensitivity of AIS detection and number of false positives were calculated for the evaluation of the test set detection results. The sensitivity of the radiologist with and without the software detection results was compared using the McNemar test. A p-value of less than 0.05 was considered statistically significant. Results: For the two-stage model and radiologist without and with the use of the software results, the sensitivity was 37.3%, 33.3%, and 41.3%, respectively, and the number of false positives per one case was 1.265, 0.327, and 0.388, respectively. On using the two-stage detection model's results, the board-certified radiologist's detection sensitivity significantly improved (p-value = 0.0313). Conclusions: Our detection system involving the two-stage deep learning model significantly improved the radiologist's sensitivity in AIS detection.
主题: 图像与视频处理 (eess.IV); 计算机视觉与模式识别 (cs.CV); 机器学习 (cs.LG)
引用方式: arXiv:2004.04432 [eess.IV]
  (或者 arXiv:2004.04432v1 [eess.IV] 对于此版本)
  https://doi.org/10.48550/arXiv.2004.04432
期刊参考: Computer Methods and Programs in Biomedicine 196 (2020) 105711
相关 DOI: https://doi.org/10.1016/j.cmpb.2020.105711

提交历史

来自:Mizuho Nishio
[v1] 2020年9月9日 星期三 00:00:00 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

eess.IV
< 上一篇   |   下一篇 >
最新 | 近期 | 2020-09
切换浏览方式为:
eess
cs.CV
cs.LG

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站