跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

电气工程与系统科学 > 信号处理

arXiv:2006.06034 (eess)
[提交于 2020年6月10日]

标题:VLSI Implementation of TDC Architectures Used in PET Imaging Systems

作者:Mehmet Akif Ozdemir, Ali Tangel
查看论文《VLSI Implementation of TDC Architectures Used in PET Imaging Systems》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Positron emission tomography (PET) is a medical imaging method based on the measurement of concentrations of positron-emitting radionuclides in a living body. In the PET imaging system, glucose is labeled with a positron-emitting radionuclide and injected intravenously. Then, the positrons move through the tissue and collide with the electrons of the cells in which they interact. As a result of this interaction, two gamma rays are emitted in the opposite direction. Gama rays emitted from cancerous tissue that has retained radioactive glucose are detected through ring-shaped detectors. And the detected signals are converted into an electrical response. Subsequently, these responses are sampled with electronic circuits and recorded as histogram matrix to generate the image set. The gamma rays may not reach the detectors located in the opposite position in equal time. In PETs having TOF characteristics, it is aimed to obtain better positioning information by a method based on the principle of measuring the difference between the reach time of the two photons to detectors. The measurement of the flight time is carried out with TDC structures. The measurement of this time difference at the ps level is directly related to the spatial resolution of the PET system. In this study, 45 nm CMOS VLSI simulations of TDC structures that have various architectural approaches were performed for use in PET systems. With the designed TDC architectures, two gamma photons time reach to detectors have been simulated and the time difference has been successfully digitized. In addition, various performance metrics such as input and output voltages, time resolutions, measurement ranges, and power analysis of TDC architectures have been determined. Proposed Vernier oscillator-based TDC architecture has been reached 25 ps time resolution with a low power consumption of 1.62681 mW at 1V supply voltage.
评论: 8 pages, in Turkish language. 6 figures, conference paper,International Marmara Sciences Congess (IMASCON 2019 SPRING), https://www.imascon.com/dosyalar/imascon2019bahar/imascon_fen_bildiriler_ciltII_bahar_2019.pdf , https://avesis.kocaeli.edu.tr/yayin/99073ee1-45ff-495e-9cab-42de4d0fad71/vlsi-implementation-of-tdc-architectures-used-in-pet-imaging-systems
主题: 信号处理 (eess.SP); 硬件体系结构 (cs.AR); 系统与控制 (cs.SY); 系统与控制 (eess.SY)
报告编号: https://www.imascon.com/dosyalar/imascon2019bahar/imascon_fen_bildiriler_ciltII_bahar_2019.pdf
引用方式: arXiv:2006.06034 [eess.SP]
  (或者 arXiv:2006.06034v1 [eess.SP] 对于此版本)
  https://doi.org/10.48550/arXiv.2006.06034
期刊参考: in Int. Marmara Sci. Congess (IMASCON 2019 Spring), 2019, pp. 1997-2003

提交历史

来自:Mehmet Akif Ozdemir
[v1] 2020年6月10日 星期三 19:00:06 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

eess.SP
< 上一篇   |   下一篇 >
最新 | 近期 | 2020-06
切换浏览方式为:
eess
cs.AR
cs.SY
eess.SY

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站