跳到正文
EasyXiv 检索
投稿 关于 登录

按回车检索 · 直接输入编号(如 1706.03762)可跳转到论文

电气工程与系统科学 > 信号处理

arXiv:2008.02228 (eess)
[提交于 2020年8月6日]

标题:Remote atrial fibrillation burden estimation using deep recurrent neural network

作者:Armand Chocron, Julien Oster, Shany Biton, Mandel Franck, Meyer Elbaz, Yehoshua Y. Zeevi, Joachim Behar
查看论文《Remote atrial fibrillation burden estimation using deep recurrent neural network》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:The atrial fibrillation burden (AFB) is defined as the percentage of time spend in atrial fibrillation (AF) over a long enough monitoring period. Recent research has demonstrated the added prognosis value that becomes available by using the AFB as compared with the binary diagnosis. We evaluate, for the first time, the ability to estimate the AFB over long-term continuous recordings, using a deep recurrent neutral network (DRNN) approach. Methods: The models were developed and evaluated on a large database of p=2,891 patients, totaling t=68,800 hours of continuous electrocardiography (ECG) recordings acquired at the University of Virginia heart station. Specifically, 24h beat-to-beat time series were obtained from a single portable ECG channel. The network, denoted ArNet, was benchmarked against a gradient boosting (XGB) model, trained on 21 features including the coefficient of sample entropy (CosEn) and AFEvidence. Data were divided into training and test sets, while patients were stratified by the presence and severity of AF. The generalizations of ArNet and XGB were also evaluated on the independent test PhysioNet LTAF database. Results: the absolute AF burden estimation error |E_AF|, median and interquartile, on the test set, was 1.2 (0.1-6.7) for ArNet and 3.1 (0.0-11.7) for XGB for AF individuals. Generalization results on LTAF were consistent with E_AF of 2.6 (1.1-14.7) for ArNet and 3.6 (1.0-16.7) for XGB. Conclusion: This research demonstrates the feasibility of AFB estimation from 24h beat-to-beat interval time series utilizing recent advances in DRNN. Significance: The novel data-driven approach enables robust remote diagnosis and phenotyping of AF.
主题: 信号处理 (eess.SP)
引用方式: arXiv:2008.02228 [eess.SP]
  (或者 arXiv:2008.02228v1 [eess.SP] 对于此版本)
  https://doi.org/10.48550/arXiv.2008.02228

提交历史

来自:Armand Chocron
[v1] 2020年8月6日 星期四 00:00:00 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

eess.SP
< 上一篇   |   下一篇 >
最新 | 近期 | 2020-08
切换浏览方式为:
eess

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站