物理学 > 原子物理
[提交于 2020年8月20日]
标题:Precision Metrology Meets Cosmology: Improved Constraints on Ultralight Dark Matter from Atom-Cavity Frequency Comparisons
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读摘要:We conduct frequency comparisons between a state-of-the-art strontium optical lattice clock, a cryogenic crystalline silicon cavity, and a hydrogen maser to set new bounds on the coupling of ultralight dark matter to Standard Model particles and fields in the mass range of $10^{-16}$ $-$ $10^{-21}$ eV. The key advantage of this two-part ratio comparison is the differential sensitivities to time variation of both the fine-structure constant and the electron mass, achieving a substantially improved limit on the moduli of ultralight dark matter, particularly at higher masses than typical atomic spectroscopic results. Furthermore, we demonstrate an extension of the search range to even higher masses by use of dynamical decoupling techniques. These results highlight the importance of using the best performing atomic clocks for fundamental physics applications as all-optical timescales are increasingly integrated with, and will eventually supplant, existing microwave timescales.
提交历史
来自:Colin Kennedy[v1] 2020年8月20日 星期四 04:50:17 UTC
当前浏览上下文:
physics.atom-ph
切换浏览方式为: