标题:Bayesian information-theoretic calibration of patient-specific radiotherapy sensitivity parameters for informing effective scanning protocols in cancer

作者:Heyrim Cho, Allison L. Lewis, Kathleen M. Storey
查看论文《Bayesian information-theoretic calibration of patient-specific radiotherapy sensitivity parameters for informing effective scanning protocols in cancer》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:With new advancements in technology, it is now possible to collect data for a variety of different metrics describing tumor growth, including tumor volume, composition, and vascularity, among others. For any proposed model of tumor growth and treatment, we observe large variability among individual patients' parameter values, particularly those relating to treatment response; thus, exploiting the use of these various metrics for model calibration can be helpful to infer such patient-specific parameters both accurately and early, so that treatment protocols can be adjusted mid-course for maximum efficacy. However, taking measurements can be costly and invasive, limiting clinicians to a sparse collection schedule. As such, the determination of optimal times and metrics for which to collect data in order to best inform proper treatment protocols could be of great assistance to clinicians. In this investigation, we employ a Bayesian information-theoretic calibration protocol for experimental design in order to identify the optimal times at which to collect data for informing treatment parameters. Within this procedure, data collection times are chosen sequentially to maximize the reduction in parameter uncertainty with each added measurement, ensuring that a budget of $n$ high-fidelity experimental measurements results in maximum information gain about the low-fidelity model parameter values. In addition to investigating the optimal temporal pattern for data collection, we also develop a framework for deciding which metrics should be utilized at each data collection point. We illustrate this framework with a variety of toy examples, each utilizing a radiotherapy treatment regimen. For each scenario, we analyze the dependence of the predictive power of the low-fidelity model upon the measurement budget.
主题: 定量方法 (q-bio.QM); 信息论 (cs.IT); 动力系统 (math.DS); 信息论 (math.IT)
引用方式: arXiv:2009.02620 [q-bio.QM]
  (或者 arXiv:2009.02620v1 [q-bio.QM] 对于此版本)
  https://doi.org/10.48550/arXiv.2009.02620

提交历史

来自:Allison Lewis
[v1] 2020年9月8日 星期二 00:00:00 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

q-bio.QM
< 上一篇   |   下一篇 >
最新 | 近期 | 2020-09
切换浏览方式为:
q-bio
cs.IT
math.DS
math.IT

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站