标题:Measurements of D-D fusion neutrons generated in nanowire array laser plasma using Timepix3 detector
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读摘要:We present the results of neutron detection in a laser plasma experiment with a CD$_2$ nanowire target. A hybrid semiconductor pixel detector Timepix3 covered with neutron converters was used for the detection of neutrons. D-D fusion neutrons were detected in a polyethylene converter through recoiled protons. Both the energy of recoiled protons and the time-of-flight of neutrons (and thus their energy) were determined. We report $(2.4 \pm 1.8) \times 10^7$ neutrons generated for 1~J of incoming laser energy. Furthermore, we proved that Timepix3 is suitable for difficult operational conditions in laser experiments.
提交历史
来自:Martin Veselsky[v1] 2020年10月28日 星期三 00:00:00 UTC