标题:Detectability assessment of an x-ray imaging system using the nodes in a wavelet packet decomposition of a star-bar object

作者:Antonio González-López
查看论文《Detectability assessment of an x-ray imaging system using the nodes in a wavelet packet decomposition of a star-bar object》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Purpose: Using linear transformation of the data allows studying detectability of an imaging system on a large number of signals. An appropriate transformation will produce a set of signals with different contrast and different frequency contents. In this work both strategies are explored to present a task-based test for the detectability of an x-ray imaging system. Methods: Images of a new star-bar phantom are acquired with different entrance air KERMA and with different beam qualities. Then, after a wavelet packet is applied to both input and output of the system, conventional statistical decision theory is applied to determine detectability on the different images or nodes resulting from the transformation. A non-prewhitening matching filter is applied to the data in the spatial domain, and ROC analysis is carried out in each of the nodes. Results: AUC maps resulting from the analysis present the area under the ROC curve over the whole 2D frequency space for the different doses and beam qualities. Also, AUC curves, obtained by radially averaging the AUC maps allows comparing detectability of the different techniques as a function of the frequency in one only figure. The results obtained show differences between images acquired with different doses for each of the beam qualities analyzed. Conclusions: Combining a star-bar as test object, a wavelet packet as linear transformation, and ROC analysis results in an appropriate task-based test for detectability performance of an imaging system. The test presented in this work allows quantification of system detectability as a function of the 2D frequency interval of the signal to detect. It also allows calculation of detectability differences between different acquisition techniques and beam qualities.
评论: 18 pages, 10 figures
主题: 医学物理 (physics.med-ph); 数据分析、统计与概率 (physics.data-an)
引用方式: arXiv:2011.14378 [physics.med-ph]
  (或者 arXiv:2011.14378v1 [physics.med-ph] 对于此版本)
  https://doi.org/10.48550/arXiv.2011.14378
相关 DOI: https://doi.org/10.1002/mp.14883

提交历史

来自:Antonio González-López
[v1] 2020年11月29日 星期日 14:41:52 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics.med-ph
< 上一篇   |   下一篇 >
最新 | 近期 | 2020-11
切换浏览方式为:
physics
physics.data-an

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站