标题:Stress shielding at the bone-implant interface: influence of surface roughness and of the bone-implant contact ratio

作者:Maria Letizia Raffa, Vu-Hieu Nguyen, Philippe Hernigou, Charles-Henri Flouzat- Lachaniette, Guillaume Haiat
查看论文《Stress shielding at the bone-implant interface: influence of surface roughness and of the bone-implant contact ratio》的 PDF
查看原文 PDF 中文 PDF (下批处理) EasyResearch 阅读
摘要:Short and long-term stabilities of cementless implants are strongly determined by the interfacial load transfer between implants and bone tissue. Stress-shielding effects arise from shear stresses due to the difference of material properties between bone and the implant. It remains difficult to measure the stress field in periprosthetic bone tissue. This study proposes to investigate the dependence of the stress field in periprosthetic bone tissue on i) the implant surface roughness, ii) material properties of bone and of the implant, iii) the bone-implant contact ratio. To do so, a microscale 2-D finite element model of an osseointegrated boneimplant interface was developed where the surface roughness was modeled by a sinusoidal surface. The results show that the isostatic pressure is not affected by the presence of the bone-implant interface while shear stresses arise due to the combined effects of a geometrical singularity (for low surface roughness) and of shear stresses at the bone-implant interface (for high surface roughness). Stress-shielding effects are likely to be more important when the bone-implant contact ratio value is low, which corresponds to a case of relatively low implant stability. Shear stress reach a maximum value at a distance from the interface comprised between 0 and 0.1 time roughness wavelength $\lambda$ and tend to 0 at a distance from the implant surface higher than $\lambda$, independently from bone-implant contact ratio and waviness ratio. A comparison with an analytical model allows validating the numerical results. Future work should use the present approach to model osseointegration phenomena.
评论: Journal of Orthopaedic Research, Wiley, In press
主题: 医学物理 (physics.med-ph); 经典物理 (physics.class-ph)
引用方式: arXiv:2012.15143 [physics.med-ph]
  (或者 arXiv:2012.15143v1 [physics.med-ph] 对于此版本)
  https://doi.org/10.48550/arXiv.2012.15143
相关 DOI: https://doi.org/10.1002/jor.24840

提交历史

来自:Maria Letizia Raffa
[v1] 2020年12月30日 星期三 13:09:12 UTC
全文链接:

访问论文:

  • 查看原文 PDF
  • 中文 PDF (下批处理)
  • EasyResearch 阅读
  • TeX 源文件
  • arXiv 原文页面
查看许可

当前浏览上下文:

physics.med-ph
< 上一篇   |   下一篇 >
最新 | 近期 | 2020-12
切换浏览方式为:
physics
physics.class-ph

参考文献与引用

  • Google Scholar
  • Semantic Scholar

BibTeX 格式的引用

EasyXiv 是独立运营的中文预印本站点,与 arXiv 及康奈尔大学无隶属关系。 论文元数据与原文来自 arXiv.org,感谢 arXiv 提供开放获取服务。
关于 · 帮助 · 投稿指南 · 版权 · arXiv 原站